3. Consideration of Agenda Items:
A. SD 19.32 Public hearing to consider the request of Edward Loper and
Jonathan McMurray for plat approval of South Section Estates, a 4-
lot minor division. The property is located on the west side of
Section Street just south of Twin Echo Court.
B. SD 19 .33
PPIN #: 18512
Public hearing to consider the request of LA Development, LLC for
Final plat approval of Pinewood, Phase 2, a 18-lot subdivision.
The property is located on the south side of Manley Road between
Saddlewood Subdivision and the City of Fairhope Soccer Complex .
PPIN #: 230553
C. SD 19.34 Public hearing to consider the request of The Teachers Retirement
Systems of Alabama for Final plat approval of Polo Place, a 3-lot
subdivision. The property is located on the north side of Polo
Ridge Blvd. just west of S. Section Street.
PPIN #: 25387
D. SD 19.35 Public hearing to consider the request of Keith Glines for plat
approval of Glines Subdivision, a 4-lot minor division . The
property is located on the north side of Bishop Road between
County Road 13 and S. Greeno Road.
PPIN #: 208295
E. SD 19.36 Public hearing to consider the request of Baldwin 4, LLC for site
plan approval of Fairhope Hardware MOP, a 6-unit multiple
occupancy project. The property is located at the northeast
corner of the intersection of Fairhope Avenue and Church Street,
at 301 Fairhope Avenue .
F. UR 19.20
PPIN #: 14359
Request of AT&T for an 11.52.11 Utility Review and approval of
the proposed installation of approximately 650 linear foot of
underground fiber optic cable. The project will run throughout
the Twin Beech Estates subdivision.
4. Old/New Business
• ZC 19 .08 Greeno Road Corridor Overlay Districts
5. Adjourn
1 SD 19.32 South Section Estates – September 5, 2019
Planning Commission
September 5, 2019
Subdivision Approval
Case: SD 19.32 South Section Estates
Project Name:
South Section Estates
Property Owner /Applicant:
Reid Loper and Cade McMurray
General Location:
On the west side of South Section
Street approximately 500’ north of
Twin Echo Court.
Project Type:
Minor Subdivision inside
Fairhope’s ETJ
Number of lots:
4
Project Acreage:
Approx. 4.5
Zoning District:
Unzoned
PPIN Number:
18512
Engineer of record:
Seth Moore, PLS
Moore Surveying, Inc.
School District:
Fairhope Elementary, Intermediate,
Middle, and High School
Report prepared by:
Mike Jeffries, QCI
City Planner
Recommendation:
Approve
-~It.-!
Ct'TV OF i.llAHOPE ZONING , ......
~ T'I.J..all.-.
II_.AH_,11111 1"!1_.D.-u
11., .... 0...,,..,.....,.0U)
-1111~
t-2v~•C....i:,1~ ...
-llt..J"Olla.,,v,~_,,
ll..S901111t~!.'tf'thOll'lt
□•..1:r .. ,._ .. 1,,..,..,,
-fl..-\_0..,,•')'liil.,t;l•""'r
fl4 "9'1c.,~o.,,.. ~--
:ii--t: 11ldil"-"a11 ei.,..
---1~$,._.,,.C_
--.zo......,..,.,._ci_
-~T-illHM~ftl'-11
-I-..JI T-.a.,_c---.SM>.eaU.-
_._. 11.1 •11na_ltrt....._.Cl.e.d
v ,,u""'......., Cl~ .... ,, ......
•ua,...,_,,u,,•~_,.,,."'
I □,~t,.,t~
M -1 • Li g ht Indus t ri al Di s tric t
2 SD 19.32 South Section Estates – September 5, 2019
Summary of Request:
Public hearing to consider the request of Reid Loper and Cade McMurray owners and applicants for a 4‐lot
minor subdivision. The property is located on the west side of South Section Street approximately 500’ south
of Twin Echo Court. The subject property is approximately 4.5 acres.
Comments:
The subject property is not zoned by the City of Fairhope but is in Fairhope’s Extra Territorial Jurisdiction and therefore
must follow Fairhope’s Subdivision Regulations. The proposed subdivision according to Fairhope’s Subdivision
Regulations is a minor subdivision and has been reviewed accordingly.
The proposed subdivision does not include the building of any infrastructure or improvements therefore a
tree protection plan, landscape plan, and other criteria required for a major subdivision is not applicable.
The proposed subdivision did not trigger a traffic study. Concerning storm water runoff none of the existing
flow patterns will be changed by this replat. The proposed subdivision exceeds the minimum lot width and
size and provides the appropriate easements and setbacks.
The new lots will be serviced by Fairhope utilities Water, Gas, Sewer, and Power. Riviera has a single phase
line in the vicinity of the 4 lots. A mutual agreement between the City of Fairhope and Riviera gives the right
to the City of Fairhope to serve power to all 4 lots.
The subdivision regulations contain the following criteria in Article IV.B.2. Approval Standards:
“2. Consistency with Plans, Regulations and Laws ‐ The Planning Commission shall not approve the
subdivision of land if the Commission makes a finding that such land is not suitable for platting and
development as proposed, due to any of the following:
a. The proposed subdivision is not consistent with the City’s Comprehensive Plan, and/or the City’s Zoning
ordinance, where applicable;
Not applicable
b. The proposed subdivision is not consistent with the City’s Comprehensive Plan or any other plan or
program for the physical development of the City including but not limited to a Master Street Plan, a Parks
Plan, a Bicycle Plan, a Pedestrian Plan, or the Capital Improvements Program;
Not applicable
c. The proposed subdivision is not consistent with these Regulations;
Meets
d. The proposed subdivision is not consistent with other applicable state or federal laws and regulations;
or
Meets
e. The proposed subdivision otherwise endangers the health, safety, welfare or property within the
planning jurisdiction of the City.”
Meets
Recommendation:
Staff recommends approval of SD 19.32
---
1 SD 19.33 Pinewood, Phase 2 – September 5, 2019
Planning Commission
September 5, 2019
Final Plat
Case: SD 19.33 Pinewood Phase 2
Project Name:
Pinewood Phase 2 Subdivision
Property Owner / Applicant:
Matt Byrne and Todd Booth
General Location: South side of
Manley Road between Saddlewood
Subdivision and the City of Fairhope
Soccer Complex.
Project Type:
Major Subdivision
Number of lots: 18 Lots
Project Acreage: 7.42 Acres
Zoning District:
R‐2 Medium Density Single Family
PPIN Number:
230553 (parent parcel)
Engineer of record:
Sawgrass Consulting, LLC.
Doug Chaffin, PE
School District:
Newton Elementary School
Fairhope Middle School
Fairhope High School
Report prepared by:
J. Buford King,
Development Services Manager
Recommendation:
Approval with conditions
CITY OF FAIRHOPE ZONING
R--A Res.Clenlll l I AOdOJlliJre OIMnct
R.1 LowOenscy Single--Fam l y
J Rl(a )
ETI'J Rl(b)
Rl(cj
R.2 r.-edtim DenslryS.-iOJt...fami~
-R-3 H~n Denuy Slngle-Fam l y
R·3 PCt-1 PaUoJCarden Srl9le F11m l y
D R-3 TH Tav.nhouse Sil.gle Famly
1111 R.-A LGW Dertsiy M uli.f arnll)'
R-5, Hlgfl OenslyOV".ell'l9 Rnlden.tia1
R-6 r.coMeHomePar'lc"Olstnd
L...1-f-'---i-....... 1-..J..L..J....L...LLJ....L...L.LJ___.:l<'.... __ -l--___ "T""_"""T_-,-~ -e. I Local Shopp,og Disll1C!
B-2 Ge11era1 Business OISuta
-11-Ja T°"'" Re son Loo;~ 9 Dis111a
1111 B-3b Tounsr Reson Commeroal Sesvke Clstnd
1111 B-AI 8ulilnflssandProlli!!s~onalDiatrid
L!•1 Llgl'lllndustfl:al Oistrict
-P-1 P1;,.~9
POO Planned Un~ OeYelopment
2 SD 19.33 Pinewood, Phase 2 – September 5, 2019
Summary of Request: Public hearing to consider the request of Sawgrass Consulting, LLC for Final Plat
Approval of Pinewood, Phase 2, an 18‐lot subdivision. The property is located on the south side of Manley
Road between Saddlewood Subdivision and the City of Fairhope Soccer Complex.
The property owner is LA Development, LLC (Mr. Matt Byrne and Mr. Todd Booth). Mr. Doug Chaffin, PE, of
Sawgrass Consulting, LLC is the applicant’s representative and engineer of record (EOR). The subject
property is approximately 7.42 acres and 18 lots are proposed. The largest lot is approximately 12,617 sq.
ft. and the smallest lot is approximately 10,500 sq. ft.
Site History
The subject property is approximately 7.42 acres situated between multiple subdivisions and the City of Fairhope
Soccer Complex. The subject property is an open field with the topography generally flat with some gentle fall to the
east.
Topographic View of Subject Property Aerial View of Subject Property
The applicant previously submitted case number ZC 18.05 requesting conditional annexation to R‐2 medium
density single family zoning district for subject property. Case # ZC 18.05 was approved during the Planning
Commission meeting on May 7, 2018 and approved by the Fairhope City Council on November 26, 2018.
The original arrangement of Pinewood Subdivision is located to the north of the subject property and
consists of 6 lots fronting on Manley Road, which are unzoned and lot 7 is the remnant parcel resulting from
the previous Pinewood subdivision case. Though subject application is identified as “Pinewood Phase 2”
subject application is technically the “Resubdivision of Lot 7 of Pinewood Subdivision” and is not necessarily
a formal “phase of development” but a Resubdivision of Lot 7. “Pinewood Phase 2” is the generally
accepted name of the Resubdivision of lot 7 so that subject application is more easily identified and
distinguished from the original Pinewood Subdivision application as well as surrounding developments.
Further, the Resubdivision of lot 7 functions as a second phase of development but must function within the
constraints created by the original Pinewood Subdivision. The final plat correctly labels the development as
“Pinewood Subdivision Phase 2, a Resubdivision of Lot 7, Pinewood Subdivision, Phase 1”.
1./
i 14 105 I 14 !06
3 SD 19.33 Pinewood, Phase 2 – September 5, 2019
As stated previously the zoning district of subject development has been established as an R‐2 Medium
Density Single Family Residential Zoning District and includes the following dimension standards:
35’ front setbacks
35’ rear setbacks
10’ side setbacks
20’ street side setbacks
37% maximum lot coverage
30’ building height
Comments:
The following items are excerpts from the staff review of Case number SD 19.33. Review comments have
been cured by the EOR’s responses to staff correspondence, and are noted in blue text, which may include
conditions of approval.
Article IV, Section C.1.b.(2) Name and Location of the Proposed Subdivision – The Baldwin County Revenue
Commission has requested that subdivisions predating the current final plat request be more easily-recognizable.
Under the “Pinewood Subdivision, Phase 2” label at the top of the plat, please include appropriate wording that
indicates the subject plat is a Resubdivision of Lot 7 of Pinewood Subdivision. The title of the plat has been
revised to reflect the subdivision of Lot 7.
Article IV, Section.D.1.a. Maintenance Bond – The Maintenance and Guaranty Agreement was not included with
the Final Plat Application. Further, the numeric and written cost amounts listed on the bond do not match.
Maintenance and Guaranty Agreement furnished as requested and the numeric and written cost estimates
on the bond have been corrected.
Article IV, Section.D.1.b.(17 Maintenance Agreement for maintenance of detention facilities – Several sections
are included in the O&M Plan and Agreement that are not applicable to subject application. (Including, but not
limited to green roofs, permeable paving, etc.). Please reflect only applicable sections in the fully-executed
O&M Plan and Agreement that is recorded. The O&M Plan and Agreement has been edited as requested
and has been signed by the developer, and is ready to be recorded upon final approval of Case # SD 19.33.
Article V, Section D.6. Street Standards – Pedestrian Area Design Standards – Please reference Matt Byrne’s e-
mail of September 20, 2018 regarding sidewalks in common areas. The sidewalks in common areas have not yet
been installed. This item will likely be a condition of approval that precludes plat approval. The EOR’s follow-
up correspondence indicates the site work contractor will install sidewalks in common areas before
August 30, 2019. Due to the publication time of the staff report, the installation of sidewalks shall be a
condition of approval, which may be removed upon verbal request by staff of the condition of approval is no
longer required at the time of the Planning Commission meeting.
Article VI, Section.B.1.- B.4. Construction Standards – Jason Christian, PE, noted the pavement wearing surface
was not in place at the time asphalt core samples were taken. Mr. Christian noted a final letter of approval will
be issued when the core samples of the wearing surface were tested. The final letter of approval from Mr.
Christian was not included with the application. The final letter of approval by the testing engineer was
furnished as requested via follow-up correspondence.
Article V, Section.D.6.a.-g. Street Standards – Pedestrian Area Design Standards – please cross reference Right
of Way Inspector Cody Johnson’s e-mail of August 9, 2019. Please address each item in this e-mail. Further,
this review assumes, by virtue of the engineer’s certificate included with the as-built drawings, that the drainage
system included with subject development is “as-built as-designed” as thus functioning properly. Due to the
publication time of the staff report, all remaining punch list items shall be a condition of approval, which may
4 SD 19.33 Pinewood, Phase 2 – September 5, 2019
be removed upon verbal request by staff if the condition of approval is no longer required at the time of the
Planning Commission meeting.
Article VI, Section G. Construction Standards-Fire Hydrants -the fire hydrant located at the east end of Silage
Drive does not contain a blue reflective marker as required by this section. Due to the publication time of the
staff report, the installation of sidewalks shall be a condition of approval, which may be removed upon verbal
request by staff of the condition of approval is no longer required at the time of the Planning Commission
meeting.
Site Photos:
The subdivision regulations contain the following criteria in Article IV.B.2. Approval Standards. Address
each of these criteria with either a “meets” or “does not meet”. If any of the criteria is not met, a denial
should be recommended.
“2. Consistency with Plans, Regulations and Laws ‐ The Planning Commission shall not approve the
subdivision of land if the Commission makes a finding that such land is not suitable for platting and
development as proposed, due to any of the following:
Looking northeast toward soccer complex
from eastern terminus of Dutch Road
Looking southeast toward soccer complex
from eastern terminus of Dutch Road
Looking west along Dutch Road toward Open
Field Drive
Looking northwest along Dutch Road toward
Open Field Drive
L____ __ I L___I --~
5 SD 19.33 Pinewood, Phase 2 – September 5, 2019
a. The proposed subdivision is not consistent with the City’s Comprehensive Plan, and/or the City’s
Zoning ordinance, where applicable;
meets
b. The proposed subdivision is not consistent with the City’s Comprehensive Plan or any other plan or
program for the physical development of the City including but not limited to a Master Street Plan, a
Parks Plan, a Bicycle Plan, a Pedestrian Plan, or the Capital Improvements Program;
meets
c. The proposed subdivision is not consistent with these Regulations;
meets
d. The proposed subdivision is not consistent with other applicable state or federal laws and
regulations; or
meets
e. The proposed subdivision otherwise endangers the health, safety, welfare or property within the
planning jurisdiction of the City.”
Meets
Recommendation:
Staff recommends APPROVAL of Case # ZC 19.33, Pinewood Subdivision Phase 2, contingent upon the
following conditions:
1) Installation of sidewalks in common areas as described in “comments”, above.
2) Completion of punch lists items identified by the Construction Inspector via separate
correspondence and also as described in “comments”, above.
3) The warranty period of the sanitary sewer lift station shall not commence until start‐initial
start‐up of the lift station and upon approval of the Water and Sewer Superintendent.
4) Reflect “Silage Drive” in lieu of “Dutch Road” as the street name on the final plat. If the
developer desires a street name change, that process may occur after the final plat process.
LOT 1LOT 2LOT 3LOT 4LOT 5LOT 6LOT 7LOT 8LOT 18LOT 17LOT 16LOT 15LOT 14LOT 13LOT 12LOT 11LOT 10LOT 9COMMON AREATOTAL ACREAGE = 1.09 ACRES± (47,480 S.F.±)DETENTION = 0.22 ACRES± (9,551 S.F.±)GREENSPACE = 0.87 ACRES± (37,897 S.F.±)COMMON AREA
TOTAL ACREAGE = 0.91 ACRES± (39,457 S.F.±)
DETENTION = 0.51 ACRES± (22,375 S.F.±)
GREENSPACE = 0.40 ACRES± (17,424 S.F.±)11143 Old Highway 31 Spanish Fort, AL 36527818 N. McKenzie Street Foley, AL 36535Phone: (251) 544-7900Phone: (251) 970-7900CHECKED BY:SHEET:DATE:DRAWN BY:OFSCALE:NUMBER:REVISION:DATE:11MARCH, 20181" = 50'LA DEVELOPMENT, LLCFINAL PLATPINEWOOD SUBDIVISION, PHASE 2A RESUBDIVISION OF LOT 7, PINEWOOD SUBDIVISION, PHASE 17 CERTIFICATE OF APPROVAL BY BALDWIN COUNTY E.M.C. (ELECTRIC) THE UNDERSIGNED, AS AUTHORIZED BY BALDWIN COUNTY E.M.C., HEREBY APPROVES THE WITHIN PLAT FOR THE RECORDING OF SAME IN THE PROBATE OFFICE OF BALDWIN COUNTY, ALABAMA. THIS THE DAY OF 2018. AUTHORIZED SIGNATURE CERTIFICATE OF APPROVAL BY FAIRHOPE GAS THE UNDERSIGNED, AS AUTHORIZED BY FAIRHOPE GAS, HEREBY APPROVES THE WITHIN PLAT FOR THE RECORDING OF SAME IN THE PROBATE OFFICE OF BALDWIN COUNTY, ALABAMA, THIS THE ____ DAY OF -------2018. (AUTHORIZED SIGNATURE) CERTIFICATE OF APPROVAL BY FAIRHOPE WATER & SEWER THE UNDERSIGNED, AS AUTHORIZED BY FAIRHOPE WATER & SEWER, HEREBY APPROVES THE WITHIN PLAT FOR THE RECORDING OF SAME IN THE PROBATE OFFICE OF BALDWIN COUNTY, ALABAMA, THIS THE ____ DAY OF _______ , 2018. (AUTHORIZED SIGNATURE) FAIRHOPE PLANNING COMMISSION THE WITHIN PLAT OF PINEWOOD SUBDIVISION, BALDWIN COUNTY, ALABAMA, IS HEREBY APPROVED BY FAIRHOPE CITY PLANNING COMMISSION. THIS THE ___ DAY OF --------2018. PLANNING DIRECTOR CERTIFICATE OF OWNERSHIP AND DEDICATION STATE OF ALABAMA COUNTY OF BALDWIN THIS IS TO CERTIFY THAT I, MA TT BYRNE, A MEMBER OF LA DEVELOPMENT, LLC. AND THE OWNER OF THE LAND SHOWN AND DESCRIBED IN THE PLAT, AND THAT I HAVE CAUSED THE SAME TO BE SURVEYED AND SUBDIVIDED AS INDICATED HEREIN, FOR THE USES AND PURPOSE HEREIN SET FORTH AND DO HEREBY ACKNOWLEDGE AND ADOPT THE SAME UNDER THE DESIGN AND TITILE HEREON INDICATED; AND GRANT ALL EASEMENTS AND DEDICATE ALL STREETS, ALLEYS, WALKS, PARKS AND OTHER OPEN SPACES TO PUBLIC OR PRIVATE USE AS NOTED TOGETHER WITH SUCH RESTRICTIONS AND COVENANTS NOTED BELOW OR ATTACHED IN A SEPARATE LEGAL DOCUMENT. DA TED THIS THE ___ DAY OF _______ _ WITNESS NAME AND TITLE CERTIFICATION BY NOTARY PUBLIC STA TE OF ALABAMA COUNTY OF BALDWIN 2018. I, ----------~ A NOTARY PUBLIC IN AND FOR THE COUNTY OF BALDWIN IN THE STATE OF ALABAMA DO CERTIFY THAT WHOSE NAME IS SUBSCRIBED TO THE CERTIFICATE OF OWNERSHIP AND DEDICATION, APPEARED BEFORE ME THIS DAY IN PERSON AND ACKNOWLEDGED THAT HE SIGNED, SEALED AND DELIVERED SAID INSTRUMENT AT THIS FREE AND VOLUNTARY ACT FOR THE USES AND PURPOSE HEREIN SET FORTH. GIVEN UNDER MY HAND AND NOTARIAL SEAL THIS THE 2018. NOTARY PUBLIC .C.R.f". .R.8,F. 0c.R.S. ----0 0::: 0 I.() .._,, 0::: Cl Cl _J w LL. z w 11.. 0 LEGEND CAPPED REBAR FOUND REBAR FOUND CAPPED REBAR SET PROPERTY LINE ~R.F.-FAIRHOPE TAX PARCEL # 05-46-D8-28-0-000-014.020 EDWARD JACKSON 106 OPEN FIELD DR FARHOPE, AL 36532 C.R.F.-EDS ~ I I I l _____ ~1 _____ J ______ L ----------,' I ml TELEPHONE PEDESTAL liIBl TELEPHONE PEDESTAL ~ SEWER VALVE F"c:> FIRE HYDRANT "' I><] WATER VALVE ENGINEERING -SURVEYING -CONSTRUCTION MANAGEMENT ' ' ~-R,F, EDS COMMON AREA SADDI...EWOOD HCl.4EOWNERS ASSOCIATION INC TAX PARCEL # 05-46-0B-28-0-000-014.011 20585 CTY RD 13 STE D FARHCPE, AL 36532 rC.IU.-HMR I SITE DATA NUMBER OF LOTS: 18 LOTS SMALLEST LOT SIZE: 75'X140' (10,500 S.F.) TOTAL AREA: 7.42 ACRES± PROPOSED ZONING: CITY OF FAIRHOPE, R2 SETBACKS: FRONT = 35 FEET REAR = 35 FEET SIDE = 10 FEET SIDE STREET = 20 FEET COMMON AREA TOTAL COMMON AREA = 2.00 ACRES± COMMON AREA FOR DETENTION = 0. 73 ACRES± COMMON AREA FOR GREENSPACE = 1.27 ACRES± (17%) GREENSPACE REQUIRED = 0.74 ACRES± (10%) OWNER LA DEVELOPMENT, LLC C/0 MA TT BYRNE 20040 HWY 181 FAIRHOPE, ALABAMA 36532 SURVEYOR /ENGINEER SAWGRASS CONSULTING, LLC 11143 OLD HIGHWAY 31 SPANISH FORT, AL 36527 SURVEYOR: ERCIL E. GODWIN, PLS ALABAMA LICENSE NUMBER f6621 ENGINEER: WILLIAM D. CHAFFI~, P.E. ALABAMA LICENSE NUMBER 32963 UTILITY PROVIDERS WATER -CITY OF FAIRHOPE SEWER -CITY OF FAIRHOPE ELECTRIC -BALDWIN EMC ENGINEER'S CERTIFICATE - --,---, t----1 --.... ----.-..::---------1 -,__--, ---,__-----, r-. I\. VICINITY I, THE UNDERSIGNED, A REGISTERED PROFESSIONAL ENGINEER IN THE STATE OF ALABAMA HOLDING CERTFlCATE NUMBER HEREBY CERTIFY THAT I HAVE REVIEWED THE DESIGN HEREIN WHICH WAS DONE UNDER MY DIRECT CONTROL AND SUPERVISION AND THAT, TO THE BEST OF MY PROFESSIONAL KNOWLEDGE AND TO THE BEST OF MY BEUEF, CONFORMS TO THE REQUIREMENTS OF THE FAIRHOPE SUBDMSION REGULATIONS AND TO All. OTHER RULES, REGULATIONS, LAWS, AND ORDINANCES APPLICABLE TO MY DESIGN. WIWAM D. CHAFFlN, PE PROJECT ENGINEER DATE GENERAL SURVEYOR'S NOTES: -- --MAP 11 GRAPmc SCALE ? ( IN FEET ) 1 Inch= 50 fl I I 1. SOURCES or INFORMATION USED TO FACILITATE THIS SURVEY WERE PREVIOUS SURVEYS BY THIS FlRM, SURVEYS BY OTHER FIRMS AND INFORMATION FURNISHED BY CLIENT. NO TITLE SEARCH, TITLE OPINION OR ABSTRACT WAS PERFORMED BY THIS FlRM. THERE MAY BE DEEDS or RECORD, UNRECORDED DEEDS, EASEMENTS, RIGHT-OF-WAYS, OR OTHER INSTRUMENTS or RECORD WHICH COULD AFFECT THE BOUNDARIES or THIS PROPERlY THAT WERE NOT FURNISHED AT TIME or SURVEY. 2. All. BEARINGS ARE BASED ON THE GRID NORTH AS DETERMINED BY RTK GPS AND REFERENCED 10 NADB3, N.JSAMA WEST STATE PLANE COORDINATES. I 3. I HAVE CONSULTED THE FEDERAL INSURANCE ADMINISTRATION ldAP, COMMUNITY PANEL NO. 01003C07BOL, EFFECTM' JULY 17, 2007, AND HAVE FOUND THAT THE DESCRIBED PROPERTY IS LOCATED IN ZONE ")("(UNSHADED), AREAS DETERMINED TO BE OUTSIDE THE 0.2:1 ANNUAL CHANCE FLOOD PLAIN. (REVIEW or THE PRELIMINARY DATA PROVIDED BY ADECA/(NIR FOR THE PROPOSED UPDATED FIRM SHOWS THE SUBJECT PROPERlY TO STILL BE WITHIN THE "X" UNSHADED ZONE) 4. FlELD WORK FOR THIS SURVEY WAS PERFORMED OCTOBER, 2016 AND FEBRUARY, 201B. 5. All'( FLOOD ZONES GIVEN OR SHOWN ON THE FACE OF THIS DRAWING ARE SCALED FROM THE FEDERAL EMERCENCY MANAGEMENT AGENCY FLOOD INSURANCE MAPS (SCALED ONLY). 6. ALL LOTS ARE SUBJECT TO THE FOLLOWING DRAINAGE AND l/TILITY EASEMENTS (UNLESS OTHERWISE SHOWN HEREON): FRONT LOT LINES -15 FEET REAR LOT LINES -15 FEET SIDE LOT LINE -7.5 FEET SIDE LOT LINES ABUTTING A RIGHT-OF-WAY -15 Fm 7. A PROPERrl' OWNERS ASSOCL'\TION (PDA) IS REQUIRED 10 BE FORMED. THE PDA 15 REQUIRED TO MAINTAIN ANY AND All. STORM WATER FACILITIES AND STRUCTURES LOCATED Ol/TSIDE OF THE ACCEPTED RIGHT-OF-WAY. B. THE GREENSPACE WILL BE A NATURAL OPEN SPACE/GREENWAY USABLE FOR RECREATION AND NON-MOTORIZED TRANSPORTATION. IT WILL INCLUDE FEW CONSTRUCTED IMPROVEMENTS EXCEPT FOR THOSE TO ENHANCE TRAVEL OR RECREATIONAL USE AND PR<MDE CONTINUITY THROUGHOL/T THE DEVELOPMENT. ALL REQUIRED GREENSPACE SHALL BE INDICATED AS A PUBLIC ACCESS AND USE EASEMENT. THE PROPERTY 15 NOT DEDICATED TO THE CITY OF FAIRHOPE AND THAT THE CITY OF FAIRHOPE 15 NOT RESPONSIBLE FOR MAINTENANCE or ANY OR All. REQUIRED GREENSPACE. RECORD DESCRIPTION: LOT 7, PINEWOOD SUBDIVISION, PHASE 1, IS RECORDED ON SLIDE 2617-F, IN THE OFFlCE OF THE JUDGE OF PROBATE, BALDWIN COUNTY, Al/>BNIA I CERTIFY THAT ALL PARTS or THIS SURVEY AND DRAWING HAVE BEEN COMPLETED IN ACCORDANCE WITH THE CURRENT REQUIREMENTS or THE STANDARDS or PRACTICE FOR LAND SURVEYING IN THE STATE OF ALABAMA TO THE BEST or MY KNOWLEDGE, INFORMATION AND BELIEF. ERCIL E. GODWIN, PLS DATE ALABAMA LICENSE NUMBER 26621 PINEWOOD SUBDIVISION, PHASE 2
1 SD 19.34 Polo Place – September 5, 2019
Planning Commission
September 5, 2019
Subdivision Approval
Case: SD 19.34 Polo Place
Project Name:
Polo Place
Site Data:
Lot 1 – 0.43 acres +/‐
Lot 2 – 0.31 acres +/‐
Lot 3 – 0.33 acres +/‐
Project Type:
Final Plat Approval Request
Jurisdiction:
Fairhope Planning Jurisdiction
Zoning District:
Unzoned Baldwin County
PPIN Number:
25387 (Parent Parcel)
General Location:
Polo Ridge BLVD, 3/8 mile south
of Battles Road
Engineer:
Goodwyn, Mills, and Cawood
Owner:
Teacher’s Retirement System of
Alabama (RSA)
School District:
J. Larry Newton Elementary
School, Fairhope Middle and High
Schools
Recommendation:
Approval
Prepared by:
J. Buford King, Development
Services Manager
t
N
1/ r
ZON\r\C
s~i;ima
~B-011111::iid
--~•itr.n~9Qllfaf;1:
, li!ff.fflC D_..:J .. ""
'-flft~fl.t.&<-a -.,_.t!•NNiludt:1, .. ~ ......
2 SD 19.34 Polo Place – September 5, 2019
Summary of Request:
Public hearing to consider the request of Goodwyn, Mills, and Cawood, Inc. (GMC) on behalf of the
Retirement Systems of Alabama (RSA) for a request for FINAL PLAT approval of Polo Place Subdivision, a
three‐lot major subdivision. Subject property is located along Polo Ridge Boulevard approximately 1/10 mile
west of South Section Street, located within the City of Fairhope planning jurisdiction within unzoned
Baldwin County. Subject property consists of approximately 13 total acres, with the new lot sizes as
indicated on the staff report cover page. Mr. Tim Lawley, PE of GMC serves as the engineer of record (EOR)
for subject application. (This subdivision was submitted by Mr. Lawley prior to the acquisition of
Hutchinson, Moore, and Raugh by GMC).
Comments:
MAJOR SUBDIVISION CRITERIA
The following items are excerpts from the staff review of Case number SD 19.34. Review issues have been
cured by the EOR’s responses to staff correspondence, and are noted in blue text, which may include
conditions of approval.
Article IV, Section.D.1.a. Maintenance Bond – The Maintenance and Guaranty Agreement is included, but not
the bond itself. The EOR clarified via follow-up correspondence that RSA is “self-bonded” and does not obtain
a surety for maintenance bond purposes. Should a maintenance issue occur, that maintenance issue will be self-
cured by RSA. The Maintenance and Guaranty agreement’s dates of execution shall serve in lieu of the bond
expiration date.
Article IV, Section.D.1.b.(18) Engineer’s Certificate – I have your engineer’s certificate in letter form; however,
the subdivision regulations require the certificate to be on the plat and plans. (It can go on the cover page of a set
of as-built drawings, but in this case, I’m asking that you place it and your PE stamp on the final plat, as well as
on the one as-built drawing for the sake of simplicity). EOR’s PE stamp and certificate have been furnished as
requested.
Article IV, Section.C.1.b.(8) Condition of approval “1” from Case number SD 19.13 – This condition of approval
required Ductile Iron Pipe (DIPS) underneath Polo Ridge BLVD, which appears to have been correctly installed
in the field as seen in the sewer inspection videos. Please revise the as-built plans and profiles to reflect DIPS as
required. The EOR clarified via follow-up correspondence the sanitary sewer pipe placed under Polo Ridge
BLVD was correctly installed using High Density Polyethylene (HDPE) pipe, however that HDPE pipe was to
be furnished in DIPS as far as sizing. The installed material and reference on the as-built drawings are both
correct, which satisfies a condition of approval from the preliminary plat approval.
Article IV, Section.C.1.b.(15) Condition of approval “3” from Case number SD19.13 – please provide the
topographic survey for file purposes. Furnished as requested.
The subdivision regulations contain the following criteria in Article IV.B.2. “Approval Standards”. Each of
these criteria is addressed below with either a “meets” or “does not meet” comment. If any of the criteria is
not met, a denial will be recommended.
2. Consistency with Plans, Regulations and Laws ‐ The Planning Commission shall not approve the
subdivision of land if the Commission makes a finding that such land is not suitable for platting and
development as proposed, due to any of the following:
a. The proposed subdivision is not consistent with the City’s Comprehensive
Plan, and/or the City’s Zoning ordinance, where applicable;
meets
b. The proposed subdivision is not consistent with the City’s Comprehensive
3 SD 19.34 Polo Place – September 5, 2019
Plan or any other plan or program for the physical development of the City including but not limited to a
Master Street Plan, a Parks Plan, a Bicycle Plan, a Pedestrian Plan, or the Capital Improvements Program;
meets
c. The proposed subdivision is not consistent with these Regulations;
Plat 1 does not meet (lot size and lot width waiver submitted)
Plat 2 meets
d. The proposed subdivision is not consistent with other applicable state or federal laws and regulations;
or
meets
e. The proposed subdivision otherwise endangers the health, safety, welfare or
property within the planning jurisdiction of the City.”
meets
Site Photos:
Recommendation:
Staff recommends APPROVAL of Case number SD 19.34 Polo Place Subdivision FINAL PLAT.
Looking northeast toward subject property
from Polo Ridge BLVD
Looking North from Polo Ridge BLVD
toward subject property
Looking northwest toward subject
property from Polo Ridge BLVD
Looking north toward common area
between Lot 1 and adjoining properties
E N G I N E E R S U R V E Y O R S S PROFESSIONAL
No. 27403
N DESECILAMABALA
SURV E Y ORS
T
UART L S MITH.
·
·
·
·
·
·
·
”
”
””
”
”
”
”
”
NO.
----------------------B.7351 ;~:~) POLO PLACE SUBDIVISION
I
I
\
I
I
I
I
/
/
----
--------
/
/
/
----
/
TAX PARCEL NO.
05-46-09-31-0-000-004.004
SMITH, MICHAEL & JUNE
2472-D PERDIDO BEACH BLVD
ORANGE BEACH, AL
LOT 60
POINT CLEAR STABLES
PHASE ONE
(SLIDE 2035 C&D)
/
, I
/ I
, , I
___,,,
I
I
~I
1 i
.;
~
5/B" CRF
(CA#568)
20.00·
GRAPlilC SCALE
,0 0 ,o
IN FEET )
I inch -30 It.
S 89"09'11" E 108.24'(A)
S 89"09'11" E 88.24'
15' DRAINAGE &: UTILllY EASEMENT ,-----------,
I
I 30' BUILDING SETBACK ,-----------------------7
I
I
TAX PARCEL NO.
05-46-09-31-0-000-001 .001
THE TEACHERS' RETIREMENT SYSTEM
OF ALABAMA
201 SOUTH UNION STREET
MONTGOMERY, AL 36104
/ 5/B" CRF I
I
S 89"10'54" E 90.00'(A)
_______________________ (CAjl56B)
TAX PARCEL NO.
05-46-09-31-0-000-004.003
DAVIS, PAUL & DAHLIA
PO BOX 2211
FAIRHOPE, AL
LOT 61
I I
I ~ 1 I __ ,~DRAINAGE~ lJTILITY EASEMEN.!_ _ 7
~< ~wll ii I I ~ I 30' BUILDING SETBACK I ~ -'1* ~II~ LOT 1 ~ I 111:1 -----------------------7, II
~ o O t:: f:; 0.43 ACRES ± G:i ~ ("I~ +l+I N ,,!JVl 18,949 S.F. ± 111: ~ I 111 : I
uJ 0: ~ u: l,w 5I" F.F.E. ~ 58.00' "1 9 I I
vo<oim ws ffilo:! a11 1lol
I
3
1/1
POINT CLEAR STABLES
PHASE ONE
{SLIDE 2035 C&D)
~ ~ 5cn •1~ '"1§ §11 ~ I ~1 r r i~
~ :! ~~ b ~I~ . I ~~ ~I ix xi I~ I
b ~ dl"1 0 iol~ e1 r-:~1 ~ I~ !aJI •
S 89"06'27" E 160.00"(A)
o e :z ,,_1 :e, ~11 :§ LOT 2 ~! 1~
1
, , _____ ,_._ ORAINAG!C_&_l!!lUlY ~E"E"' ______ 7
z I ·~"I ~ 1., I 1~ I ------------------------==IP I '"11~ 0.31 ACRES± ~I ,Id I-I %~~5~~ I I 01, !1 ll ~}:~.1
:
5
{i_5~• ai :~~: i: r ____________ JO' BUILDING~~Af.~-----------------J~
TAX PARCEL NO.
05-46-09-31-0-000-004.002
PIECZYNSKI, JAMES & MARY
17662 HITCHING POST CIRCLE
FAIRHOPE, AL
LOT 62
POINT CLEAR STABLES
PHASE ONE
{SLIDE 2035 C&D)
1 I 0"'
611 ~I:~ :e: 1~81 ~I I~ ,:,I~ I I »I 1 , 1· -1c I~ ;i;I r.: I 1, ~Lu 211111 LOT 3 t::ilie I I I :::, I(!) CII ....I I I I • I I z 0.33 ACRES ± " I I I 0 1 ~ 10 ~j=' I I I II I I ~1 wl I§ 14,528 S.F. ± 91'" I I [ I I b i1 i~ F.F.E. = 68.00' ~~ I L ______ _:l~_B':"~~-"-~~"-----J I L. _______ 30' BUILD<NG SETBACK ____ JI :, ~I [ 30' BUILDING SETBACK ~:1
I I : I I I ~ I ------------------------------------------
1 I I I I I ~I ~
15.00'
I
I
I
1/1
P.O.B. l L _,~DRAINAGE~ UTILITY EASEMEN..!._ _ --,1 L 15' DRAINAGE&: UTILITY EASEMENT _j L , I
SOUTHEAST _j_ ----- -- - - - - -I _____ 15 DRAINAGE Ile LJTILITY EASEMENT ______ _J
1/2" CRF CORNER I ---------1!YSIDEWAL~-EASEMENT ________ --t ---------------------------1---------------------------t.,
&£.CA#101) _____________ O~T-~2 I 20.00' I S 89.05,59 ,. E 95 00' 1D.OO S 89 _05 , • , 10' SIDEWALK EASEMENT -------tr/
N 89"17'50" W 109.64'(A) 5/B" CRF-4 CMS • 59 E 90.?0 • S 89'05'59" E 145.00' " 15.00' /
N--,,,r'I',--W--w--W--W--(CA#56B)W--w--w--W--W--w--W--W--W--N 89"0559 W 365,QO'(A) -----1-~------------------
W • •--•--•--w--w--w--w--w--w--w--w--w--w-
..... " •·. . .. -: ........
POLO RIDGE BOULEVARD ------CENTERLINE --------------------(60' R.O.W, AS PER TAX PLAT) -------------------________ _
(VARIABLE R.O.W. AS PER SLIDE 2017 C&D) --------,s-p,w:_r_ ROAD---
...
--. ---------------------------,r •• ... • -------------------------------• • • • ,r . • • • "'· •••• ---1~RCP--------------------------------------------------------------------------------------
C. BE 8 li'E
I
I
I
I
I
I
I
•-. .... ·.
-· . ..
(CcuRB ~
OWNER/DEVELOPER
THE TEACHERS' RETIREMENT SYSTEM OF ALABAMA
THE EMPLOYEES' RETIREMENT SYSTEM OF ALABAMA
201 SOUTH UNION STREET
MONTGOMERY, AL 36104
llattlcs
l'oint Clear
... ------kc=,',,'
l , .. ~
\,~~ 7 8
SITE DATA
TAX PARCEL NO. VICINITY MAP NOT TO SCALE
05-46-09-31-0-000-001.001
TOTAL SITE AREA -1.21 ACRES± (52,497 S.F.±}
TOTAL NUMBER OF LOTS -3
SMAU.EST LOT -0.31 ACRES± (13,513 S.F.±)
LARGEST LOT -0.43 ACRES± {18,949 S.F.±)
DENSl1Y -2.48 UNrrs PER ACRE
ZONING
BALDWIN COUN1Y DISTRICT 17, UNZONED
Cl1Y OF FAIRHOPE EXTRA TERRITORIAL JURISDICTION
PROPOSED USE: RESIDENTIAL
GREENSPACE
COMMON AREA 1 & 2 -0.12 ACRES± (5,502 S.F.±}
GREENSPACE -10.5%
ZONING REQUIREMENTS
30' FRONT SETBACK
30' REAR SETBACK
1 O' SIDE SETBACK
100' MINIMUM LOT WIDTH AT THE STREET
t!QIE: AS PER THE HIGHWAY CONSTRUCTION SETBACK
ENABLING LEGISLATION FOR BALDWIN COUN1Y, AL, ACT NO.
94-572, THE MINIMUM SETBACK REQUIREMENT MEASURED FROM
THE CENTERLINE OF THE RIGHT-OF-WAY IS 40' ALONG POLO
RIDGE BLVD.
DEDICATED EASEMENTS
7.5' UTILl1Y & DRAINAGE EASEMENT ON BOTH SIDES OF ALL
INTERIOR LOT LINES.
15' UTILl1Y & DRAINAGE EASEMENT ALONG THE SUBDIVISION
PERIMETER SIDE AND REAR BOUNDARY LINES.
RIVIERA UTILITIES HAS A DEDICATED 1 O' UTILl1Y EASEMENT
ALONG ALL SIDE LOT LINES AND A 15' UTILl1Y EASEMENT
ALONG ALL ROAD SIDE AND REAR LOT LINES.
UTILITIES
POWER
SEWER
WATER
PHONE
GAS
-RIVIERA UTILITIES
-FAIRHOPE WATER &
-FAIRHOPE WATER &
-AT&T
-FAIRHOPE GAS
SEWER
SEWER
GENERAL SURVEYOR'S NOTES
LEGEND
P.O.C. POINT OF COMMENCEMENT
P.O.B. POINT OF BEGINNING
(A) ACTUAL
(R) RECORD DEED
(P) PLAT OF RECORD
(C) COMPUTED
OTIF OPEN TOP IRON PIPE FOUND
IPF IRON PIN FOUND
CTIF CRIMP TOP IRON PIPE FOUND
CRF CAPPED REBAR FOUND
RBF 1/2" REBAR FOUND
CRS 1/2" CAPPED REBAR SET STAMPED CA#604
CMF CONCRETE MONUMENT FOUND
CMS CONCRETE MONUMENT SET
LS# LICENSED PROFESSIONAL SURVEYOR'S NUMBER
CA/I CERTIFICATE OF AUTHORIZATION NUMBER
(DIST) DISTURBED
(REF) REFERENCE CORNER SET ON LINE
(UNR) UNREADABLE
INST # INSTRUMENT NUMBER
SECT. SECTION
T-TOWNSHIP
R-RANGE
-0-POWER POLE
E--GLN WIRE
R/W RIGHT-OF-WAY
R.O.W. RIGHT-OF-WAY
0 FIRE HYDRANT _,,.. SIGN
Im TELEPHONE PEDESTAL
~ ELECTRIC METER BOX
~ AIR CONDmONER
~ JUNCTION BOX (VAULT)
EL/ELEV ELEVATION
INV INVERT
•~:
ALL CORNERS ARE "CRS" UNLESS OTHERWISE STATED.
; TELEPHONE BOX (VAULT)
WATER METER
ft SANITARY SEWER VALVE
WATER VALVE
l1)l GAS VALVE
cr!I TRANSFORMER BOX
)c( LIGHT POLE
el CABLE TV BOX
~ ELECTRIC BOX
~ ELECTRIC PANEL
l!1d' IRRIGATION CONTROL VALVE
® SANITARY SEWER MANHOLE
@ STORM DRAIN MANHOLE
CD TELEPHONE MANHOLE
@ SEWER CLEANOUT
e!I SEWER GRINDER PUMP
el GREASE TRAP a,._ FLAG POLE
® GAS LINE SIGN MARKER
& TELEPHONE SIGN MARKER
£ WATERLINE MARKER
£ FlBER OPTIC LINE MARKER
(EX.) EXCEPTION
-FO-UNDERGROUND FIBER OPTIC LINE
-OE-OVERHEAD ELECTRIC
-BE-BURIED ELECTRIC LINE
-UT-UNDERGROUND TELEPHONE UNE
-s-UNDERGROUND SEWER LINE
-w-UNOERGROUND WATERLINE
-G-UNDERGROUND GAS LINE
-,V-UNDERGROUND TELEVISION
'8 #-Bl' SPOT GRADE ELEVATIONS
CMP CORRUGATED MITAL PIPE
RCP REINFORCED CONCRETE PIPE
CPP CORRUGATED PLASTIC PIPE
1 .
2.
SOURCES OF INFORMATION USED TO FACILITATE THIS SURVEY WERE PREVIOUS SURVEYS BY THIS AND OTHER FIRMS, THE RECORDED
SUBDIVISION PLAT, AND/OR OTHER RECORDED DOCUMENTS SHOWN HEREON.
3.
4.
5.
6.
7.
8.
9.
NO TITLE SEARCH, TITLE OPINION OR ABSTRACT WAS PERFORMED BY THIS FIRM. THERE MAY BE DEEDS OF RECORD, UNRECORDED DEEDS,
EASEMENTS, RIGHT-OF-WAYS, OR OTHER INSTRUMENTS OF RECORD WHICH COULD AFFECT THE BOUNDARIES OF THIS PROPERTY THAT WERE
NOT FURNISHED AT TIME OF SURVEY.
FIELD WORK FOR THIS SURVEY WAS COMPLETED ON 12/11/2018.
All. BEARINGS ARE BASED ON NORTH AMERICAN DATUM 1983, ALABAMA WEST ZONE; STATE PLANE GRID NORTH; DERIVED BY GLOBAL
POSITIONING SYSTEM OBSERVATION; ALL DISTANCES SHOWN ARE GROUND DISTANCES. ALL MEASUREMENTS WERE MADE IN ACCORDANCE WITH
U.S. STANDARD FEET.
THE SURVEYED PROPER1Y IS LOCATED WITHIN AN AREA HAVING A ZONE DESIGNATION OF "X" BY THE FEDERAL EMERGENCY MANAGEMENT
AGENCY (FEMA), AS SCALED FROM FLOOD INSURANCE RATE MAP NO. 01003C0756L, WITH A REVISED DATE OF IDENTIFICATION OF JULY 17,
2007, FOR COMMUNl1Y NO. 015000, IN BALDWIN COUN1Y, STATE OF ALABAMA.
NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED UNLESS SHOWN.
ALABAMA ONE CALL WAS CONTACTED TO HAVE THE UNDERGROUND UTILITIES MARKED FOR LOCATION ON 12/D5/2018 {TICKET # 183391049).
ANY EXISTING UNDERGROUND UTILITIES NOT SHOWN HEREON WERE NOT MARKED AT THE TIME OF THIS SURVEY. THE SURVEYOR MAKES NO
GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED.
THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED, BUT THE
UTILITIES ARE SHOWN AS THEY WERE MARKED IN THE FIELD.
THIS IS A BOUNDARY SURVEY FOR SUBDIVISION.
THE SURVEYED PROPER1Y LIES WITHIN SECTION 31, TOWNSHIP 6 SOUTH, RANGE 2 EAST.
LEGAL DESCRIPTION
I r □ □
0 DE BE BE e;B E--BE BE
-G"-===-c .=:=::f --BE--BE--BE--BE--01!,
-G-G-G-
□ □ □ □ □ □ □
----------,~-Rep~-.~~'=-,·\
BE--BE--BE--BE--BE--BE--BE--BE--BE--BE-e ,t..\_
E_8£_Bf_Bf -----------~p~ □ --□----□ ---□----□11 ~"CM; □----□ --□ --□ --r
1
1/2"0;F-~--~--~--~~R~~;SF:::~--
A PORTION OF TAX PARCEL NUMBER 05-46-09-31-0-000-001.001 LYING WITHIN SECTION 31, TOWNSHIP 6 SOUTH, RANGE 2 EAST,
BALDWIN COUN1Y, ALABAMA, BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS:
BEGINNING AT A 5/8 IRON REBAR WITH CAP {CA#568) AT THE SOUTHEAST CORNER OF LOT 62 OF POINT CLEAR STABLES, PHASE
ONE, AS SHOWN ON PLAT THEREOF RECORDED ON SLIDE 2035 C & D IN THE OFFICE OF THE JUDGE OF PROBATE RECORDS,
BALDWIN COUN1Y, ALABAMA, SAID POINT ALSO LYING ON THE NORTH RIGHT-OF-WAY OF POLO RIDGE BOULEVARD AS SHOWN ON SAID
SLIDE 2035 C & D; THENCE RUN NORTH 00'19'48" EAST ALONG THE EAST LINE OF SAID SUBDIVISION A DISTANCE OF 200.01 FEET
TO A 1/2 IRON REBAR WITH CAP (CA#604); THENCE LEAVING SAID EAST LINE SOUTH 89'09'11" EAST A DISTANCE OF 108.24 FEET
TO A 1/2 IRON REBAR WITH CAP (CA#604); THENCE RUN SOUTH 21'41'21" EAST A DISTANCE OF 18.03 FEET TO A 1/2 IRON
REBAR WITH CAP (CA#604); THENCE RUN SOUTH 00'19'50" WEST A DISTANCE OF 33.35 FEET TO A 1/2 IRON REBAR WITH CAP
(CA#604); THENCE RUN SOUTH 89'10'54" EAST A DISTANCE OF 90.00 FEET TO A 1/2 IRON REBAR WITH CAP (CA#604); THENCE
REVISION DATE ENGR.
TAX PARCEL NO.
05-46-09-31-0-000-008.000
LAY, MARTHA ANN
P.O. BOX 342
POINT CLEAR, AL
HMR
TAX PARCEL NO. TAX PARCEL NO. I
05-46-09-31-Q-QQQ-062.001 I 05-46-09-31-Q-QQQ-062.000 I
McCANTS, RON & LATONYA McCANTS, CLAYTON 1
2810 BRENTWOOD DRIVE P.O. BOX 1032
BAY MINETTE, AL POINT CLEAR, AL
HUTCHINSON, MOORE & RAUCH, LLC
2039 MAIN STREET
DAPHNE, ALABAMA
36526
• TEL (251) 626-2626
(251) 626-6934
daphne@hmrengineers.com
RUN SOUTH 00"19'50" WEST A DISTANCE OF 50.05 FEET TO A 1/2 IRON REBAR WITH CAP (CA#604); THENCE RUN SOUTH 89'06'27"
EAST A DISTANCE OF 160.00 FEET TO A 1/2 IRON REBAR WITH CAP {CA#604); THENCE RUN SOUTH 00'19'50" WEST A DISTANCE OF
100.21 FEET TD A 1/2 IRON REBAR WITH CAP {CA#604) ON SAID NORTH RIGHT-OF-WAY; THENCE RUN NORTH 89'05'59" WEST
ALONG SAID NORTH RIGHT-OF-WAY A DISTANCE OF 365.00 FEET TO THE POINT OF BEGINNING; SAID DESCRIBED PARCEL CONTAINING
1.21 ACRES, MORE OR LESS AND LYING WITHIN SECTION 31, TOWNSHIP 6 SOUTH, RANGE 2 EAST, BALDWIN COUN1Y, ALABAMA.
SURVEYOR'S CERTIFICATION
I HEREBY STATE THAT ALL PARTS OF THIS SURVEY AND DRAWING HAVE BEEN COMPLETED IN ACCORDANCE WITH THE CURRENT REQUIREMENTS OF
THE STANDARDS OF PRACTICE FOR LAND SURVEYING IN THE STATE OF ALABAMA TO THE BEST OF MY KNOWLEDGE, INFORMATION AND BELIEF.
STUART L. SMITH, PLS DATE
ALABAMA LICENSE NUMBER 27403
*DRAWING IS INVALID WITHOUT SIGNATURE & SEAL OF A LICENSED LAND SURVEYOR
,,11 ,,,,
POLO PLACE SUBDIVISION ,,, ,,, ~
0 ~ .•·········•. /,,
I-~ ~ .•· ·•. ~ -.... ·-.. -FINAL PLAT --:5' -f \ -a. ~ . . ' . I r-CLIENT . . RSA . . ~ -t -. . -. . -. . --•,. -·· -..... co ~ .. .. ~ '• .. -.j-~ SCALE DATE DRAWN BY CHECKED BY SHEET / .......... ' // ,, ,, \\ ..... 1"=30' AUGUST 2019 TBS SLS 1 OF 11 11111111'' a,: 2
PROFESSIONAL
No. 27403
N DESECILAMABALA
SURV E Y ORS
T
UART L S MITH.
E N G I N E E R S U R V E Y O R S S
NO. REVISION
POLO PLACE SUBDIVISION
CERTIFICATE OF OWNERSHIP
STATE OF ALABAMA
COUNTY OF BALDWIN
THIS IS TO CERTIFY THAT THE TEACHERS' RETIREMENT SYSTEM OF ALABAMA
IS THE OWNER OF THE LAND SHOWN AND DESCRIBED IN THE PLAT, AND
THAT I HAVE CAUSED THE SAME TO BE SURVEYED AND SUBDIVIDED AS
INDICATED HEREIN, FOR THE USES AND PURPOSE HEREIN SET FORTH AND
DO HEREBY ACKNOWLEDGE AND ADOPT THE SAME UNDER THE DESIGN AND
TITLE HEREON INDICATED; AND GRANT ALL EASEMENTS FOR UTILITY USE AS
NOTED TOGETHER WITH SUCH RESTRICTIONS AND COVENANTS NOTED BELOW
OR ATTACHED IN A SEPARATE LEGAL DOCUMENT.
DATED THIS THE ___ µAY OF ___ 20
THE TEACHERS' RETIREMENT SYSTEM OF ALABAMA
NOTARY FOR TEACHERS' RETIREMENT SYSTEM OF ALABAMA
STATE OF ALABAMA
COUNTY OF MONTGOMERY
I, ________________ THE UNDERSIGNED AUTHORITY, A
NOTARY PUBLIC IN AND FOR SAID COUNTY IN SAID STATE, HEREBY CERTIFY THAT
DAVID G. BRONNER, WHOSE NAME AS SECRETARY-TREASURER OF THE TEACHERS'
RETIREMENT SYSTEM OF ALABAMA, AN INSTRUMENTALITY OF THE STATE OF ALABAMA,
IS SIGNED TO THE FOREGOING INSTRUMENT, AND WHO IS KNOWN TO ME,
ACKNOWLIEDGED BEFORE ME ON THIS DAY THAT, BEING INFORMED OF THE CONTENTS
OF SAID INSTRUMENT, HE, AS SUCH SECRETARY-TREASURER AND WITH FULL
AUTHORITY, EXECUTED THE SAME VOLUNTARILY FOR AND AS THE ACT OF SAID PUBLIC
CORPORATION.
GIVEN UNDER MY HAND AND OFFICIAL SEAL THIS THE
NOTARY PUBLIC
MY COMMISSION EXPIRES: ______ _
CERTIFICATE OF OWNERSHIP
STATE OF ALABAMA
COUNTY OF BALDWIN
DAY OF ____ 20
THIS IS TO CERTIFY THAT THE EMPLOYEES' RETIREMENT SYSTEM OF
ALABAMA IS THE OWNER OF THE LAND SHOWN AND DESCRIBED IN THE PLAT,
AND THAT I HAVE CAUSED THE SAME TO BE SURVEYED AND SUBDIVIDED AS
INDICATED HEREIN, FOR THE USES AND PURPOSE HEREIN SET FORTH AND
DO HEREBY ACKNOWLEDGE AND ADOPT THE SAME UNDER THE DESIGN AND
TITLE HEREON INDICATED; AND GRANT ALL EASEMENTS FOR UTILITY USE AS
NOTED TOGETHER 'MTH SUCH RESTRICTIONS AND COVENANTS NOTED BELOW
OR ATTACHED IN A SEPARATE LEGAL DOCUMENT.
DATED THIS THE ___ µAY OF __ _ 20
THE EMPLOYEES' RETIREMENT SYSTEM OF ALABAMA
NOTARY FOR EMPLOYEES' RETIREMENT SYSTEM OF ALABAMA
STATE OF ALABAMA
COUNrTY OF MONTGOMERY
I, =~~=~=~~=====~~THE UNDERSIGNED AUTHORITY, A NOTARY
PUBLIC IN AND FOR SAID COUNTY IN SAID STATE, HEREBY CERTIFY THAT DAVID G.
BRONNER, WHOSE NAME AS SECRETARY-TREASURER OF THE EMPLOYEES' RETIREMENT
SYSTEM OF ALABAMA, AN INSTRUMENTALITY OF THE STATE OF ALABAMA, IS SIGNED TO
THE FOREGOING INSTRUMENT, AND WHO IS KNOWN TO ME, ACKNOWLEDGED BEFORE ME
ON THIS DAY THAT, BEING INFORMED OF THE CONTENTS OF SAID INSTRUMENT, HE, AS
SUCH SECRETARY-TREASURER AND WITH FULL AUTHORITY, EXECUTED THE SAME
VOLUNTARILY FOR AND AS THE ACT OF SAID PUBLIC CORPORATION.
GIVEN UNDER MY HAND AND OFFICIAL SEAL THIS THE ____ AY OF
20
NOTARY PUBLIC
MY COMMISSION EXPIRES: ______ _
CERTIFICATE OF APPROVAL BY AT&T
THE UNDERSIGNED, AS AUTHORIZED BY AT&T HEREBY APPROVES THE WITHIN
PLAT FOR THE RECORDING OF SAME IN THE PROBATE OFFICE OF BALDWIN
COUNrTY, ALABAMA,
THIS THE ___ _ DAY OF ------~ 20
AUTHORIZED SIGNATURE
CERTIFICATE OF APPROVAL BY FAIRHOPE WATER AND SEWER
THE UNDERSIGNED, AS AUTHORIZED BY FAIRHOPE WATER & SEWER, HEREBY
APPROVES THE WITHIN PLAT FOR THE RECORDING OF SAME IN THE PROBATE OFFICE
OF BALDWIN COUNTY, ALABAMA.
THIS THE ___ DAY OF ______ 20
AUTHORIZED SIGNATURE
CERTIFICATE OF APPROVAL BY FAIRHOPE GAS
THE UNDERSIGNED, AS AUTHORIZED BY FAIRHOPE GAS, HEREBY APPROVES
THE WITHIN PLAT FOR THE RECORDING OF SAME IN THE PROBATE OFFICE OF
BALDWIN COUNTY, ALABAMA.
THIS THE ___ DAY OF ______ 20
AUTHORIZED SIGNATURE
CERTIFICATE OF APPROVAL BY THE RIVIERA UTILITIES
THE UNDERSIGNED, AS AUTHORIZED BY THE RIVIERA UTILITIES, HEREBY
APPROVES THE WITHIN PLAT FOR THE RECORDING OF SAME IN THE PROBATE
OFFICE OF BALDWIN COUNTY, ALABAMA.
THIS THE ____ DAY OF -----------20
AUTHORIZED SIGNATURE
CERTIFICATE OF APPROVAL BY THE COUNTY ENGINEER
THE UNDERSIGNED, AS COUNTY ENGINEER OF BALDWIN COUNrTY, ALABAMA, HEREBY
APPROVES THE WITHIN PLAT FOR THE RECORDING OF SAME IN THE PROBATE OFFICE OF
BALDWIN COUNTY, ALABAMA,
THIS ___ DAY OF __________ 20
AUTHORIZED SIGNATURE
CERTIFICATE OF APPROVAL BY
THE BALDWIN COUNTY E-911 ADDRESSING
THE UNDERSIGNED, AS AUTHORIZED BY THE BALDWIN COUNTY E-911 BOARD,
HEREBY APPROVES THE WITHIN PLAT FOR THE RECORDING OF SAME IN THE
PROBATE OFFICE OF BALDWIN COUNTY, ALABAMA,
THIS ___ DAY OF __________ 20
AUTHORIZED SIGNATURE
CERTIFICATE OF APPROVAL OF THE CITY OF FAIRHOPE
PLANNING COMMISSION
THE 'MTHIN PLAT OF POLO PLACE SUBDIVISION, BALD'MN COUNTY, ALABAMA,
IS HEREBY APPROVED BY FAIRHOPE CITY PLANNING COMMISSION.
THIS THE ___ DAY OF _______ 20
SECRETARY
CERTIFICATION QF ENGINEER
I, THE UNDERSIGNED, A REGISTERED ENGINEER IN THE STATE OF ALABAMA HOLDING CERTIFICATE
NUMBER 30859, HEREBY CERTIFY THAT I HAVE DESIGNED THE WITHIN IMPROVEMENTS IN CONFORMITY
WITH APPLICABLE CODES AND LAWS AND WITH THE PRINCIPALS OF GOOD ENGINEERING PRACTICE. I
FURTHER CERTIFY THAT I HAVE OBSERVED THE CONSTRUCTION OF THE WITHIN IMPROVEMENTS, THAT
THE SAME CONFORMS TO MY DESIGN, THAT THE WITHIN IS A TRUE AND ACCURATE REPRESENTATION
OF IMPROVEMENTS AS INSTALLED AND THAT SAID IMPROVEMENTS ARE HEREBY RECOMMENDED FOR
ACCEPTANCE BY THE CITY OF FAIRHOPE, ALABAMA.
TIMOTHY D. LAWLEY, P.E.
AL. LICENSE #30859
DATE
HMR HUTCHINSON, MOORE & RAUCH, LLC
0 POLO PLACE SUBDIVISION
I-~ :5, FINAL PLAT ~ ~-----------------------------------------------
DATE ENGR.
2039 MAIN STREET
DAPHNE, ALABAMA
36526
• TEL (251) 626-2626
(251) 626-6934
daphne@hmrengineers.com
1 r-CLIENT ~ -t RSA ..... ~1-----------.-----------,.--------,.-------.-----------1
-.j-~ ..... a,:
SCALE DATE
N/A AUGUST 2019
DRAWN BY
SLS
CHECKED BY
SLS
SHEET
2 OF 2
E N G I N E E R S U R V E Y O R SS PROFESSIONAL
No. 27403
N DESECILAMABALA
SURV E Y ORS
T
UART L S MITH.
·
·
·
·
·
·
·
”
”
””
”
”
”
”
”
NO. REVISION DATE ENGR.
POLO PLACE SUBDIVISION
HMR HUTCHINSON, MOORE & RAUCH, LLC
2039 MAIN STREET
DAPHNE, ALABAMA
36526
• TEL (251) 626-2626
(251) 626-6934
daphne@hmrengineers.com
OWNER/DEVELOPER
THE TEACHERS' RETIREMENT SYSTEM OF ALABAMA
THE EMPLOYEES' RETIREMENT SYSTEM OF ALABAMA
201 SOUTH UNION STREET
MONTGOMERY, AL 36104
SITE DATA
TAX PARCEL NO.
05-46-09-31-0-000-001.001
TOTAL SITE AREA -1.21 ACRES± (52,497 S.F.±}
TOTAL NUMBER OF LOTS -3
SMALLEST LOT -0.31 ACRES± (13,513 S.F.±)
LARGEST LOT -0.43 ACRES± {18,949 S.F.±)
DENSITY -2.48 UNrrs PER ACRE
ZONING
BALDWIN COUNTY DISTRICT 17. UNZONED
CITY OF FAIRHOPE EXTRA TERRITORIAL JURISDICTION
PROPOSED USE: RESIDENTIAIL
GREENSPACE
COMMON AREA 1 & 2 -0.12 ACRES± (5,502 S.F.±}
GREENSPACE -10.5%
ZONING REQUIREMENTS
30' FRONT SETBACK
30' REAR SETBACK
1 O' SIDE SETBACK
100' MINIMUM LOT WIDTH AT THE STREET
t!QIE: AS PER THE HIGHWAY CONSTRUCTION SETBACK
ENABLING LEGISLATION FOR BALDWIN COUNTY, AL, ACT NO.
94-572, THE MINIMUM SETBACK REQUIREMENT MEASURED FROM
THE CENTERLINE OF THE RIGHT-OF-WAY IS 40' ALONG POLO
RIDGE BLVD.
DEDICATED EASEMENTS
7.5' UTILITY & DRAINAGE EASEMENT ON BOTH SIDES OF ALL
INTERIOR LOT LINES.
P.O.C.
P.O.B.
(A)
(R)
(P)
(C)
OTIF
IPF
CTIF
CRF
RBF
CRS
CMF
CMS
LS#
CA#
(DIST)
(REF)
(UNR)
INST #
SECT.
T-
R-
l'oint Clear
···--···-kc=,',, '
l , .. ~
\,~~ 7 8
VICINITY MAP NOT TO SCALE
LEGEND
POINT OF COMMENCEMENT ; TELEPHONE BOX (VAULT)
POINT OF BEGINNING WATER METER
ACTUAL ft SANITARY SEWER VALVE
RECORD DEED WATER VALVE
PLAT OF RECORD l1)l GAS VALVE
COMPUTED cr!I TRANSFORMER BOX
OPEN TOP IRON PIPE FOUND )c( LIGHT POLE
IRON PIN FOUND el CABLE TV BOX
CRIMP TOP IRON PIPE FOUND ~ ELECTRIC BOX
CAPPED REBAR FOUND ~ ELECTRIC PANEL
1/2" REBAR FOUND ~ IRRIGATION CONTROL VALVE
1/2" CAPPED REBAR SET STAMPED CA#604 ® SANITARY SEWER MANHOLE
CONCRETE MONUMENT FOUND @ STORM DRAIN MANHOLE
CONCRETE MONUMENT SET CD TELEPHONE MANHOLE
LICENSED PROFESSIONAL SURVEYOR'S NUMBER @ SEWER CLEANOUT
CERTIFICATE OF AUTHORIZATION NUMBER e!I SEWER GRINDER PUMP
DISTURBED el GREASE TRAP
REFERENCE CORNER SET ON LINE a,._ FLAG POLE
UNREADABLE ® CAS LINE SIGN MARKER
INSTRUMENT NUMBER & TELEPHONE SIGN MARKER
SECTION £ WATERLINE MARKER
TOWNSHIP £ FlBER OPTIC LINE MARKER
RANGE (EX.) EXCEPTION
15' UTILITY & DRAINAGE EASEMENT ALONG THE SUBDIVISION
PERIMETER SIDE AND REAR BOUNDARY LINES.
-0-POWER POLE -FO-UNDERGROUND FIBER OPTIC LINE
E--GLN WIRE -OE-OVERHEAD ELECTRIC
RIVIERA UTILITIES HAS A DEDICATED 1 O' UTILITY EASEMENT
ALONG ALL SIDE LOT LINES AND A 15' UTILITY EASEMENT
ALONG ALL ROAD SIDE AND REAR LOT LINES.
R/W
R.O.W.
0
RIGHT-OF-WAY -BE-BURIED ELECTRIC LINE
RIGHT-OF-WAY -UT-UNDERGROUND TELEPHONE UNE
FIRE HYDRANT -s-UNDERGROUND SEWER LINE
UTILITIES
POWER
SEWER
WATER
PHONE
GAS
_,,.. SIGN -w-UNDERGROUND WATERLINE
Im TELEPHONE PEDESTAL -G-UNDERGROUND GAS LINE
-RIVIERA UTILITIES ~ ELECTRIC METER BOX -lV-UNDERGROUND TELEVISION
-FAIRHOPE WATER & SEWER ~ AIR CONDmONER "8 #-Bl' SPOT GRADE ELEVATIONS
-FAIRHOPE WATER & SEWER ~ JUNCTION BOX (VAULT) CMP CORRUGATED MITAL PIPE
-AT&T ELEVATION RCP REINFORCED CONCRETE PIPE
-FAIRHOPE GAS
EL/ELEV
INV INVERT CPP CORRUGATED PLASTIC PIPE
•~:
ALL CORNERS ARE "CRS" UNLESS OTHERWISE STATED.
GENERAL SURVEYOR'S NOTES
1. SOURCES OF INFORMATION USED TO FACILITATE THIS SURVEY WERE PREVIOUS SURVEYS BY THIS AND OTHER FIRMS, THE RECORDED
SUBDIVISION PLAT, AND/OR OTHER RECORDED DOCUMENrrs SHOWN HEREON.
2. NO TITLE SEARCH, TITLE OPINION OR ABSTRACT WAS PERFORMED BY THIS FIRM. THERE MAY BE DEEDS OF RECORD, UNRECORDED DEEDS,
EASEMENrrs, RIGHT-OF-WAYS, OR OTHER INSTRUMENTS OF RECORD WHICH COULD AFFECT THE BOUNDARIES OF THIS PROPERTY THAT WERE
NOT FURNISHED AT TIME OF SURVEY.
3. FIELD WORK FOR THIS SURVEY WAS COMPLETED ON 12/11/2D18.
4. AUL BEARINGS ARE BASED ON NORTH AMERICAN DATUM 1983, AILABAMA WEST ZONE; STATE PLANE GRID NORTH; DERIVED BY GLOBAL
POSITIONING SYSTEM OBSERVATION; ALL DISTANCES SHOWN ARE GROUND DISTANCES. ALL MEASUREMENTS WERE MADE IN ACCORDANCE WITH
U.S. STANDARD FEET.
5. THE SURVEYED PROPERTY IS LOCATED WITHIN AN AREA HAVING A ZONE DESIGNATION OF "X" BY THE FEDERAL EMERGENCY MANAGEMENT
AGENCY (FEMA). AS SCALED FROM FLOOD INSURANCE RATE MAP NO. D1003C0756L. WITH A REVISED DATE OF IDENTIFICATION OF JULY 17,
2007, FOR COMMUNITY NO. 015000, IN BALDWIN COUNTY, STATE OF ALABAMA.
6. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED UNLESS SHOWN.
7. ALABAMA ONE CAILL WAS CONTACTIED TO HAVE THE UNDERGROUND UTILITIES MARKED FOR LOCATION ON 12/05/2018 (TICKET # 183391049).
ANY EXISTING UNDERGROUND UTILITIES NOT SHOWN HEREON WERE NOT MARKED AT THE TIME OF THIS SURVEY. THE SURVEYOR MAKES NO
GUARANTEE THAT THE UNDERGROUND UTIUTIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED.
THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED, BUT THE
UTILITIES ARE SHOWN AS THEY WERE MARKED IN THE FIELD.
8. THIS IS A BOUNDARY SURVEY FOR SUBDIVISION.
9. THE SURVEYED PROPERTY LIES WITHIN SECTION 31, TOWNSHIP 6 SOUTH, RANGE 2 EAST.
LEGAL DESCRIPTION
A PORTION OF TAX PARCEL NUMBER 05-46-09-31-0-000-001.001 LYING WITHIN SECTION 31, TOWNSHIP 6 SOUTH, RANGE 2 EAST,
BALDWIN COUNTY. ALABAMA. BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS:
BEGINNING AT A 5/8 IRON REBAR WITH CAP (CA#568) AT THE SOUTHEAST CORNER OF LOT 62 OF POINT CLEAR STABLES, PHASE
ONE, AS SHOWN ON PLAT THEREOF RECORDED ON SLIDE 2035 C & D IN THE OFFICE OF THE JUDGE OF PROBATE RECORDS,
BALDWIN COUNTY, ALABAMA, SAID POINT ALSO LYING ON THE NORTH RIGHT-OF-WAY OF POLO RIDGE BOULEVARD AS SHOWN ON SAID
SLIDE 2035 C & D; THENCE RUN NORTH 00"19'48" EAST ALONG THE EAST LINE OF SAID SUBDIVISION A DISTANCE OF 200.01 FEET
TO A 1/2 IRON REBAR WITH CAP (CA#604); THENCE LEAVING SAID EAST LINE SOUTH 89"09'11" EAST A DISTANCE OF 108.24 FEET
TO A 1/2 IRON REBAR WITH CAP (CA#604); THENCE RUN SOUTH 21'41'21" EAST A DISTANCE OF 18.03 FEET TO A 1/2 IRON
REBAR WITIH CAP (CA#604); THENCE RUN SOUTH 00"19'50" WEST A DISTANCE OF 33.35 FEET TO A 1/2 IRON REBAR WITH CAP
(CA#604); THENCE RUN SOUTH 89'10'54" EAST A DISTANCE OF 90.00 FEET TO A 1/2 IRON REBAR WITH CAP (CA#604); THENCE
RUN SOUTH 00-19'50" WEST A DISTANCE OF 50.05 FEET TO A 1/2 IRON REBAR WITH CAP (CA#604); THENCE RUN SOUTH 89'06'27"
EAST A DISTANCE OF 160.00 FEET TO A 1/2 IRON REBAR WITH CAP (CA#604); THENCE RUN SOUTH 00'19'50" WEST A DISTANCE OF
100.21 FEET TO A 1/2 IRON REBAR WITH CAP (CA#604) ON SAID NORTH RIGHT-OF-WAY; THENCE RUN NORTH 89'05'59" WEST
ALONG SAID NORTH RIGHT-OF-WAY A DISTANCE OF 365.00 FEET TO THE POINT OF BEGINNING; SAID DESCRIBED PARCEL CONTAINING
1.21 ACRES, MORE OR LESS AND LYING WITIHIN SECTION 31, TOWNSHIP 6 SOUTH, RANGE 2 EAST, BALDWIN COUNTY, ALABAMA.
SURVEYOR'S CERTIFICATION
I HEREBY STATIE THAT ALL PARTS OF THIS SURVEY AND DRAWING HAVE BEEN COMPLETED IN ACCORDANCE WITH THE CURRENT REQUIREMENTS OF
THE STANDARDS OF PRACTICE FOR LAND SURVEYING IN THE STATE OF ALABAMA TO THE BEST OF MY KNOWLEDGE, INFORMATION AND BELIEF.
STUART L. SMITH, PLS DATE
ALABAMA LICENSE NUMBER 27403
*DRAWING IS INVALID WITHOUT SIGNATURE & SEAIL OF A LICENSED LAND SURVEYOR
,,11 ,,,, POLO PLACE SUBDIVISION ,,, I// ~
0 ~ .•·········•. /,,
I-~ ~ .•· ·•. ~ -.... ·· .. -FINAL PLAT --:5 ........ -f \ -a. ~ . . . . I r,.. CLIENT . . RSA . . ~ -t -. . -. . -. . --•,. .•· -r,.. co ~ .. .. ~ '• .. -.j-~ SCALE DATE DRAWN BY CHECKED BY SHEET ,,
•••····••• ' // ,, ,, \\ r,.. 1"=30' AUGUST 2019 TBS SLS 1 OF 11 //111111 1' a,: 2
1 SD 19.35 Glines Subdivision – September 5, 2019
Planning Commission
September 5, 2019
Subdivision Approval
Case: SD 19.35 Glines Subdivision
Project Name:
Glines Subdivision
Property Owner /Applicant:
Keith Glines
General Location:
The property is located on the
north side of Bishop Road
between County Road 13 and
S. Greeno Road.
Project Type:
Minor Subdivision inside
Fairhope’s ETJ
Number of lots:
3
Project Acreage:
5
Zoning District:
Unzoned
PPIN Number:
208259
Engineer of record:
Dewberry Engineers Inc.
School District:
J Larry Newton, Fairhope Middle,
Fairhope High School
Report prepared by:
Mike Jeffries, QCI
City Planner
Recommendation:
Approve with conditions
Subject Property
Le;.r1d
!-------...1.--+---.r---.... ---..----J...-----~---l-s.j!IO•Al'(al
:==:;::::::::::============~======~==~:='.::::::::I
C::tTY Of' .FAl!UtO"f. ZONmO
Zonhg
11_.llua.Mll"t._tk,_,
1.,....-... 10......,,.,.._,,,...l ...
11f1u
11/Q
a,,tw..,..~~t~
-Jl-l ~pCI~~--,
l .:Jl"l:l"'l'~8el!S_,.h•I)'
0 .... 1 .... '-'-•!nfl•'-tf
-ll,...fl.twO-r,.koltJ •-r
111-$"_.0--,.u,Cl;,,;i;fot,-.,.
11,41,1_..,._tl.MCI..,._
---•IM"'i ...... c-
2 SD 19.35 Glines Subdivision – September 5, 2019
Summary of Request:
Public hearing to consider the request of Keith Glines owner and applicant for a 3‐lot minor subdivision. The
property is located on the north side of Bishop Road between County Road 13 and S. Greeno Road near the
Fairhope Airport. The subject property is approximately 5 acres and the applicant wishes to divide the
property into three residential lots with one common area around the existing lake. The applicant has
provided a letter from Baldwin County exempting it from the County’s Subdivision Regulations.
Comments:
Baldwin County has an exemption in their regulations for family subdivisions if a certain criteria is met. The
City of Fairhope’s Subdivision Regulations does not recognize this exemption. The subject property is in
Fairhope’s Extra Territorial Jurisdiction and therefore must follow Fairhope’s Subdivision Regulations. The
proposed subdivision according to Fairhope’s Subdivision Regulations is a minor subdivision and has been
reviewed accordingly. The applicant has received approval for this subdivision, and it meets the County’s
requirements for the family exemption which includes that “Each parcel shall have its own ingress/egress
and utility access of not less than 30 feet in width”. Fairhope’s Subdivision Regulations Article V Section E.3.a
states that all lots shall front upon a paved, publicly maintained street. The proposed subdivision does not
front on a paved, publicly maintained street and the applicant has requested a waiver.
The proposed subdivision does not include the building of any infrastructure or improvements therefore a
tree protection plan, landscape plan, and other criteria required for a major subdivision is not applicable.
The proposed subdivision did not trigger a traffic study. Concerning storm water runoff none of the existing
flow patterns will be changed by this replat. The lots will be serviced by private wells for water and septic
tanks for sewer. Power is supplied by Riviera Utilities.
The subdivision is in the Airport Overlay Zone and it is noted on the plat.
Waiver Request:
Article V Section E.3.a states “except as provided in Section D.6., all lots shall front upon a paved, publicly
maintained street. Double frontage lots are prohibited, except where lots consist of more than 66% of a
block”.
The applicants wish to subdivide the property utilizing a 30.02’ ingress/egress & drainage/utility easement to
access lots 1, 2, & 3 as approved by Baldwin County for an Exempt Family Subdivision. They have requested
a waiver from this requirement and provided documentation for why it is necessary. (Letter attached)
A. WAIVER STANDARDS: (Staff response in red)
Waivers may be granted where the Planning Commission finds that the following conditions exist:
1. An extraordinary hardship may result from strict compliance with these regulations due to unusual
topographic or other physical conditions of the land or surrounding area not generally applicable to other
land areas.
‐ The waiver standards contemplate more, areas that are currently zoned. Therefore, an extraordinary
hardship requirement based on unusual topography or physical characteristics for this site is not
appropriate. The hardship would be the crossing of jurisdictions between the City of Fairhope and Baldwin
County. The parcel being divided is also landlocked between other parcels with its only access being an
easement to Bishop Road.
2. The condition is beyond the control of the sub‐divider.
‐ Not applicable for this individual case.
3. The requested waiver will not have the effect of nullifying the purpose and intent of the regulations,
the Zoning Ordinance, or the Comprehensive Plan.
3 SD 19.35 Glines Subdivision – September 5, 2019
‐ The subject property lies outside of the corporate limits of Fairhope therefore, nullifying this
standard. Any building or land disturbance would have to permitted through Fairhope’ Building Department.
4. The waiver is the minimum deviation from the required standard necessary to relieve the hardship;
‐ The minimum deviation of the requested waiver from each lot fronting upon a paved, publicly
maintained road is compliance with Baldwin County’s requirement of a minimum of 30’ ingress/egress
easement. This is a continuation of an existing easement providing access to Bishop Road.
5. The waiver shall not have an adverse effect on adjacent landowners, or future landowners, or the
public;
‐ The proposed subdivision is a family subdivision and the lots have access via an easement that is
required by Baldwin County and will not have an adverse effect.
6. The waiver is necessary so that substantial justice is done.
‐ Staff is neutral on this standard. There is not substantial justice to be done. This is a jurisdiction
difference and Baldwin County whom will have final jurisdiction has approved the subdivision with the
32.03.’ easement.
The subdivision regulations contain the following criteria in Article IV.B.2. Approval Standards:
“2. Consistency with Plans, Regulations and Laws ‐ The Planning Commission shall not approve the
subdivision of land if the Commission makes a finding that such land is not suitable for platting and
development as proposed, due to any of the following:
a. The proposed subdivision is not consistent with the City’s Comprehensive Plan, and/or the City’s Zoning
ordinance, where applicable;
Not applicable
b. The proposed subdivision is not consistent with the City’s Comprehensive Plan or any other plan or
program for the physical development of the City including but not limited to a Master Street Plan, a Parks
Plan, a Bicycle Plan, a Pedestrian Plan, or the Capital Improvements Program;
Not applicable
c. The proposed subdivision is not consistent with these Regulations;
Meets
d. The proposed subdivision is not consistent with other applicable state or federal laws and regulations;
or
Meets
e. The proposed subdivision otherwise endangers the health, safety, welfare or property within the
planning jurisdiction of the City.”
Meets
Recommendation:
Staff recommends approval of SD 19.35 conditional upon the following:
1. Recommendation of approval of Waiver request from the Subdivision Regulation Article V Section E.3.a be
approved.
2. Amend general note 1 on the plat to also reflect a 15’ rear utility easement per Riviera Utilities
requirements.
---
1 SD 19.36 Fairhope Hardware MOP – September 5, 2019
Planning Commission
September 5, 2019
Multiple Occupancy Project Approval
Case: SD 19.36 Fairhope Hardware MOP
Project Name:
Fairhope Hardware MOP
Property Owner /Applicant:
FSTC/Baldwin 4, LLC
General Location:
Northeast corner of Fairhope
Avenue and North Church Street
at 301 Fairhope Avenue
Project Type:
Multiple Occupancy Project
Number of units:
6
Project Acreage:
.20 acres
Zoning District:
B‐2 General Business District
Inside the Central Business District
PPIN Number:
14359
Engineer of record:
Larry Smith
S.E. Civil Engineering and Surveying
Report prepared by:
Mike Jeffries, QCI
City Planner
Recommendation:
Approve with conditions
I
i
i J 5 04
_j_. ____________ _
3 5 f '3
Subject Property
t.ev•nd -~·--ClfV OF FAUU·IOPE ZONrUO ,_ ...
~1ll1--II:__,
11 .. ~1,Uillllall .... .,._.Da"
■.,~o.,_.,,~,-.
•-=Q-•-ci....,,
_w..,-11 .. -~~
• ...,."-"--c.~s.-.c,-111
1 • ...,. .,.--~o-
•"·• up-.....iio .. io ...........
·~
L:J
I 5cu:,
~
N
2 _50 1 ~I t 2503
2 SD 19.36 Fairhope Hardware MOP – September 5, 2019
Summary of Request:
Public hearing to consider the request of S.E. Civil on behalf of Baldwin 4, LLC owner and applicant for a six‐
unit Multiple Occupancy Project approval. The project is remodeling an existing historic building to house up
to six units. The property is located at the northeast corner of Fairhope Avenue and North Church Street at
301 Fairhope Avenue. The subject property is .20 acres.
Comments:
The proposed project is a multiple Occupancy Project (MOP) which falls under Fairhope’s Subdivision
Regulations. An MOP is not a traditional subdivision requiring the division of property into separate lots but
rather uses one property to accommodate multiple units. Therefore, not all requirements for preliminary
and final plat approval are applicable. Every MOP is unique in its design and function and are reviewed
accordingly. This project is also located in the Central Business District Overlay allowing for different
standards and requirements.
The proposed project is working to retain the historical standing of the current structure. The majority of the
work on the outside is to restore the original façade and the intent for the remodel work on the inside is to
convert the space into two floors. The bottom floor is to be used for commercial/retail and the second floor
is to be used for office space in accordance with Fairhope’s current Comprehensive Plan. The request is for a
total of 6 units. The current intent is to have 4 units on the bottom floor and 1 unit on the second floor. The
tenants are not known at this point and the request for six units allows for the possibility to split the second
floor into two office units if needed.
Below is an exert from a checklist used to review the application and is also noted as a condition of approval.
Article IV, Section C.6. a. and b. Expiration and Revocation
6. Expiration and Revocation -
a. Any substantial deviation from the approved submittals during construction or failure to provide for traffic control,
safety, environmental protection controls and/or best management practices and restoration of the site shall be
grounds for the immediate suspension of the Preliminary Plat Approval and/or issuance of a stop work order. The
Planning Commission shall have the power to reinstate Preliminary Approval when it is satisfied that conditions
resulting in suspension have been mitigated.
b. If a final plat is not submitted within two years or less after preliminary approval has been given, the preliminary
approval shall expire and the preliminary plat shall be null, void and of no force or effect.
☐N/A ☒Accepted with comments ☐Revise and Resubmit per
comments
Comments: For the applicant’s information please note the expiration and revocation requirements above.
Though subject project is an MOP and does not require separate approval of a final plat, the requirements of
paragraph “a” are a condition of approval.
3 SD 19.36 Fairhope Hardware MOP – September 5, 2019
Additional Comments:
‐ Parking and greenspace are not required subject property is in the CBD
o No dwelling units to require parking
o Preexisting building and CBD require build to lines to the right‐of‐way line
‐ Sidewalk widths are met
‐ Storm water and drainage is to remain the same and drain via sheet flow to the alley. Improvements to
the gutter system are being made to bring the water to ground level. Currently dropping down the wall.
‐ Adequate utilities can be provided. Fairhope will service the building with water, electric, and sewer. Gas
is available but not desired for the proposed project and not being designed for it at this time.
o Applicant is working with all utilities for placement of meters and areas where service is available
from the right‐of‐way.
o Locations will be finalized during the Building Permit Review and checked for building code
compliance.
‐ The applicant, Richard Peterson Director of Operations, and Richard Johnson Public Works Director are
working together to coordinate this project with City projects in the vicinity.
Approval Standards
Address each of these criteria with either a “meets” or “does not meets”. If any of the criteria is not met, a
denial should be recommended.
“2. Consistency with Plans, Regulations and Laws ‐ The Planning Commission shall not approve the
subdivision of land if the Commission makes a finding that such land is not suitable for platting and
development as proposed, due to any of the following:
a. The proposed subdivision is not consistent with the City’s Comprehensive Plan, and/or the City’s Zoning
ordinance, where applicable;
meets
b. The proposed subdivision is not consistent with the City’s Comprehensive Plan or any other plan or
program for the physical development of the City including but not limited to a Master Street Plan, a Parks
Plan, a Bicycle Plan, a Pedestrian Plan, or the Capital Improvements Program;
meets
c. The proposed subdivision is not consistent with these Regulations;
meets
d. The proposed subdivision is not consistent with other applicable state or federal laws and regulations;
or
meets
e. The proposed subdivision otherwise endangers the health, safety, welfare or property within the
planning jurisdiction of the City.”
meets
Recommendation:
Staff recommends approval of SD 19.36 Fairhope Hardware MOP with the following conditions:
1. Article IV, Section C.6. a. Expiration and Revocation
a. Any substantial deviation from the approved submittals during construction or failure to provide for
traffic control, safety, environmental protection controls and/or best management practices and
restoration of the site shall be grounds for the immediate suspension of the Preliminary Plat Approval
and/or issuance of a stop work order.
-
----
TRASH CANS TO BE ALONG
ALLEY SCREENED BY
BUILDING WALLS
80' RIGHT-OF-WAY
PAVED STREET
PARKING
EXISTING BUILDINGCONCRETE WALK"X" Marked on Brick
CONCRETE CURB
BRICK WALK
20' ALLEY
PAVED ALLEY
FAIRHOPE AVENUE WOOD DECK WITH ROOFPARKINGCHURCH STREET66' RIGHT-OF-WAYPAVED STREETNORTH 125.0'SOUTH 125.0'EAST 70'
EDGE OF
A
S
P
H
A
L
T
WEST 70.0'
EXISTING BUILDING
TO BE REMODELED
HVAC UNITS ON
ROOF
8.2'8.0'
EXISTING CONCRETE
SIDEWALK
EXISTING BRICK
PAVER SIDEWALK
PROPOSED RAMP
PROPOSED
COURTYARD
400 5 10 20
10 SCALE
SHEET
C01
20190516
GPW
DRAWN
DATE
SCALE
JOB No.
7/23/19
1"=10'SEALAFFIXREVISIONDATER
Know what's below.
before you dig.Call SITE PLAN & PEDESTRIANCIRCULATIONCONTRACTOR SHALL BE RESPONSIBLE FOR ALL RELOCATIONS, INCLUDING BUT NOT LIMITED
EXISTING STRUCTURES WITHIN CONSTRUCTION LIMITS ARE TO BE ABANDONED, REMOVED OR
RELOCATED AS NECESSARY. ALL COST SHALL BE INCLUDED IN THE BASE BID.
TO ALL UTILITIES, STORM DRAINAGE, SIGNS, TRAFFIC SIGNALS & POLES, ETC. AS REQUIRED
FOR SITE WORK. ALL WORK SHALL BE IN ACCORDANCE WITH GOVERNING AUTHORITIES
ALL DIMENSIONS AND RADII ARE TO THE FACE OF CURB UNLESS OTHERWISE NOTED.
CONDITIONS SHALL BE VERIFIED TO BE TRUE AND ACCURATE PRIOR TO BEGINNING WORK.
THE SURVEY OF EXISTING CONDITIONS IS SHOWN WITHIN THESE PLANS. ALL EXISTING
THIS SITE IS ZONED B-2 (CBD) (CITY OF FAIRHOPE).
NOTIFY CITY OF FAIRHOPE INSPECTIONS 24 HOURS BEFORE THE BEGINNING OF EVERY
PHASE OF CONSTRUCTION.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED GOVERNMENTAL
A COPY OF THE APPROVED LAND DISTURBANCE PLAN AND PERMIT SHALL BE PRESENT ON SITE
WHENEVER LAND DISTURBANCE ACTIVITY IS IN PROGRESS.
ALL TRAFFIC CONTROL SIGNS AND MARKINGS USED ON THE SITE WILL CONFORM WITH THE
MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD), FHWA, LATEST EDITION.
REFERENCE THE SIGN CODES CONTAINED IN THE MUTCD FOR ALL TRAFFIC CONTROL SIGNS.
NOTE THE COLOR AND SIZE OF ALL PAVEMENT MARKINGS, REFERENCING DETAILS IN ALDOT'S
ROADWAY AND TRAFFIC DESIGN STANDARDS WHERE APPLICABLE.
SITE PLAN NOTES
REGULATIONS AND CODES AS WELL AS O.S.H.A. AND ALDOT STANDARDS.
ALL WORK AND MATERIALS SHALL COMPLY WITH THE CITY OF FAIRHOPE
THE CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH ALL OF THE EXISTING CONDITIONS
AT THE SITE; INCLUDING UTILITIES, SURFACES, ETC. AND SHALL BE FULLY RESPONSIBLE FOR
ANY DAMAGES THEY CAUSE TO NEW AND EXISTING CONSTRUCTION, PROPERTY AND ANY
UNAUTHORIZED DISRUPTION TO UTILITIES ON SITE AND TO ADJACENT PROPERTIES.
PRIOR TO CONSTRUCTION, EXISTING UTILITIES AT PROPOSED CONNECTIONS AND CROSSINGS
SHALL BE FIELD EXCAVATED TO VERIFY LOCATIONS, ELEVATION AND SIZE. NOTIFY THE
ENGINEER IMMEDIATELY WITH ANY DEVIATIONS OR CONFLICTS.
TOTAL SITE ACREAGE = ±0.20 ACRES.
INSPECTIONS.
SPECIFICATIONS AND SHALL BE APPROVED BY SUCH. ALL COST SHALL BE INCLUDED IN BASE BID.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
PROPOSEDEXISTING
SITE PLAN LEGEND
TRAFFIC CONTROL ARROW
CURB & GUTTER
STANDARD PARKING QUANTITY
MEDIUM DUTY ASPHALT PAVING
X" SYSL - X" WIDE SINGLE YELLOW SOLID LINE
X" DYSL - X" WIDE DOUBLE YELLOW SOLID LINE
X" SWSL - X" WIDE SINGLE WHITE SOLID LINE
ACCESSIBLE PARKING SPACE
CONCRETE PAVING
PERVIOUS CONCRETE PAVING
HEADER CURB
RIBBON CURB
BUILDING (UNDER ROOF)
SITE ANALYSIS
7,474 SF
SITE ACREAGE (PROPOSED)
±0.20 AC (8,737 SF)
BUILDING SETBACKS:
FRONT YARD:
SIDE YARD:
REAR YARD:
MAXIMUM BUILDING HEIGHT:
0 FT
0 FT
0 FT
40'
BUILDING HEIGHT
±30 FT
PROVIDED PARKING
0 SPACES
REQUIRED PARKING
0 SPACES
MAX. GROUND COVERAGE RATIO:N/A
JURISDICTION
FAIRHOPE
PERVIOUS AREA
0.00 AC (0.0%)
IMPERVIOUS AREA
0.20 AC (100.0%)
REQUIRED:
PROPERTY AREA
LAND USAGE
--0.20 ACRES
BUILDING AREA (UNDER ROOF)--0.17 AC
IMPERVIOUS PAVING (EXCLUSIVE OF BLDG.) 0.03 ACRES
PERVIOUS PAVING 0.00 ACRES
DESCRIPTION % OF PROPERTY AREAAREA
100.0%
0.0%
GRASSED/LANDSCAPED AREA 0.00 ACRES 0.0%
ZONING
B-2 (CBD)
PROPOSED BUILDING COVERAGE:7,474 SF (85.5%)
CONTRACTOR SHALL REFER TO THE ARCH. PLANS FOR EXACT LOCATIONS AND DIMENSIONS
OF EXIT PORCHES; PRECISE BUILDING DIMENSIONS AND EXACT BUILDING UTILITY ENTRANCE
LOCATIONS.
THE DIMENSIONS SHOWN ARE TO THE FACE OF BUILDING UNLESS OTHERWISE NOTED.
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED UNTIL ALL SITE IMPROVEMENTS HAVE BEEN
COMPLETED.
X
THE CONSTRACTOR SHALL REFER TO THE ARCHITECTURAL PLANS FOR STAIR DETAILS.Fairhope Hardware MOP301 Fairhope AvenueFairhope, AL 36532N/F
05-46-03-37-0-601-002.523
FST PARKING AUTHORITY OF
THE CITY OF FAIRHOPE
336 FAIRHOPE AVENUE
FAIRHOPE, AL 36532
N/F
05-46-03-37-0-601-003.514
FST, REID, JAMES H JR ETAL
REID, BEVERLY
PO BOX 638
MONTROSE, AL 36559
ADJACENT PROPERTY
OWNERS
N/F
05-46-03-37-0-601-003.511
FST BETHEA, JOHN W
PO BOX 205
FAIRHOPE, AL 36533
1
2
3
ALL SIGNAGE SHALL BE IN COMPLIANCE WITH THE CITY OF FAIRHOPE SIGN ORDINANCE.
THE CONTRACTOR SHALL PROVIDE THE CITY OF FAIRHOPE A STAGING PLAN FOR
CONSTRUCTION. A PRE-CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO
COMMENCEMENT OF DEMOLITION ACTIVITIES. COORDINATION WITH THE BUILDING
DEPARTMENT WILL BE NECESSARY DURING DEMOLITION AND CONSTRUCTION.
ALL SITE LIGHTING SHALL BE IN COMPLIANCE WITH THE CITY OF FAIRHOPE ZONING ORDINANCE.
SITE LIGHTING SHALL BE ARRANGED AS TO NOT NEGATIVELY EFFECT ADJACENT PROPERTIES.
PROPOSED GREEN SPACE:0.00 AC
20.
GROSS FLOOR AREA
12,407 SF
1ST FLOOR - 4 UNITS - COMMERCIAL / RETAIL - 7,371 SF
SPACE USAGE
2ND FLOOR - 2 UNITS - OFFICE - 5,036 SF
Civil Engineering& Surveying880 HOLCOMB BLVDSUITE 2FFAIRHOPE, AL 36532251-990-6566SITE
FAIRHOPE AVECHURCH ST12
3
4
5 6
7
N/F
05-46-03-37-0-601-003.501
FST, GRIFFIN FAMILY LLC
PO BOX 1710
DAPHNE, AL 36526
N/F
05-46-03-37-0-602-002.501
FST BETHEA, JOHN W
PO BOX 205
FAIRHOPE, AL 36533
N/F
05-46-03-37-0-602-001.501
FST BETHEA, JOHN W
PO BOX 205
FAIRHOPE, AL 36533
4
5
6
N/F
05-46-03-37-0-601-002.513
FST BETHEA, JOHN W
PO BOX 205
FAIRHOPE, AL 36533
7
ADJACENT PROPERTY OWNERS MAP KEY
N.T.S.~
----
' ' ' ' ' 1 ___ _
m:-;----II
_,
,
'
... -... ,
, ' , ' ' ,
' ' ' , ' -
0 0
0
0 0
0
0
0
0
0
SIP
0
;-J
I
0
0
0
• •
0 0
~ ~
.·.·· .J I .. .. .. . . J I
I J I LI I
I J I I -
1 UR 19.20 AT&T – September 5, 2019
Planning Commission
September 5, 2019
Utility Review
Case: UR 19.20 AT&T
Project Name:
AT&T Fiber Optic Installation
throughout Fairhope’s ROW
Project Type:
Utility Review
Project Scope:
Install 650’ of Fiber Optic Cable
Via Directional bore.
Jurisdiction:
City of Fairhope
Zoning District:
ROW
General Location:
Twin Beech Estates Subdivision
Applicant:
AT&T
Owner:
City of Fairhope Right‐of‐Ways
Prepared by:
Mike Jeffries, QCI
City Planner
Recommendation:
Approve with Conditions
Le,g•nd
_,._.,IMIIP...-oa!
CtTYOF'F'AIIIIHOl't ZOW.NC , .....
=ta,...,...11....,.
a•~~"-',.,. • .,...,o,r,1\:1
.. , Uw0'"'"'"""""'"....,
All(• .,,.,
JIIICI
111,t "tll'o-4)Cl.....t"1 -.-
_ ._. filllltol•Aot..,. • ....._0 _
... ,i..,;,.,,S,,...,..t~
WCJ--•~O-o
-a..i.~•-IMtoo!-t~ • .._ ,-. .. .--c~,~-~---
-._. ~•--~ ... ~01w,c,1
.ll,II.ILJl'!I ____ ID_
........ ~1111'111
"1.ICl'"""""llnei>r,,,i,....,.
D •...-c.iu,i
j N -t
I _ l<I --h~~~~~:;;~~~;~-::::__~-=:
N
t
R-A • ResidentiilUAgriculture District
------------iliJ
1-------===:::j -t---~--1
¥ 1-----------j • 1---~--
ll
?...!.illl
2 UR 19.20 AT&T – September 5, 2019
Twin Beech Estates
Summary of Request: Request of AT&T for an 11.52.11 Utility Review and approval of the proposed underground
installation of approximately 650 linear feet of fiber optic cable or drop and 1.5” and 2” HDPE conduit within the City
of Fairhope’s ROW’s. The installation will be a directional bore where indicated on drawings in the Twin Beech Estates
Subdivision. The project will require the boring under the road in Twin Beech Estates in various locations as indicated
on the drawings provided to provide service.
i
i
i
i
i ~
~-c..._·_
3 UR 19.20 AT&T – September 5, 2019
Comments:
The proposed utility construction falls within the Corporate limits of Fairhope. The comments below are typical
general comments for City of Fairhope right‐of‐way projects. Any portions of the project affecting public right‐of‐way
(ROW) maintained by Baldwin County or the Alabama Department of Transportation (ALDOT) shall require permits
through the Baldwin County Highway Department or ALDOT.
GENERAL COMMENTS
No open trenches shall be allowed. Directional boring shall be used in sensitive areas, such as under roads, in
proximity to trees, on finished lots, etc.
SUPERINTENDENT AND DEPARTMENT HEAD COMMENTS
The applicant shall contact Alabama One Call to locate all existing utilities.
Public Works Standard Comments:
Handholes shall not be located within driplines of Heritage Trees (as defined by the Tree Ordinance).
Any proposed trenching shall not be within the dripline of trees.
If within a tree dripline, consult with the City of Fairhope Horticulturist before proceeding with earth work.
Trees shall not be negatively impacted.
The applicant shall provide drawings locating their utilities with other utilities and the sidewalks. Any
boxes/handholes cannot be placed in the sidewalk. The applicant shall review the sidewalk plan to determine if there
are any conflicts. The applicant shall coordinate work with Richard D. Johnson, PE, Public Works Director, to resolve
any potential conflicts.
All conduit/cable shall be placed at depth from existing grade per industry and/or County Standards. A minimum
horizontal and/or vertical clearance (separation) of 36” must be maintained from stormwater and utility
infrastructures. No handholes, boxes, or other above ground infrastructure shall be installed within drainage
easements. Pedestals shall be placed in a manner as to avoid obstructing visibility of motorists and to allow vehicles
to exit the roadway during an emergency. No grade change shall result from the utility installation. The applicant is to
avoid any tree drip lines with handholes and equipment.
The material under the sidewalk shall be compacted and the repair work shall be to the satisfaction of the Building
Official or his designated representative. The applicant shall contact the Building Department for inspection prior to
placing concrete.
Code Enforcement Officer’s Standard Comments:
The applicant, or subcontractor, shall obtain a ROW permit from the City of Fairhope Building Department
prior to beginning work.
Subcontractors shall have a current business license with the City of Fairhope and shall have a copy of the
ROW permit available for review at all times, and shall be posted on site or in the window of contractor’s
vehicles.
Any ROW cuts shall be stabilized (covered) at the end of each day and disturbed areas shall be re‐vegetated
with sod within ten (10) days of completion of the project.
Mulch / seed shall only be acceptable as temporary cover.
Sod shall be watered as needed to ensure survival.
Inlets shall be protected.
If site is within 100' of a critical area (wetland, etc.), no red soils/clay are allowed as fill material, per the City’s
Red Clay/Soil Ordinance.
Building Official’s Standard Comments:
4 UR 19.20 AT&T – September 5, 2019
BMP’s shall be installed at boring sites and trench locations.
Ground conditions in the ROW’s shall be returned to original preconstruction condition(s) or better.
All plans and permits shall be available for review at all times along with the City of Fairhope permit
application.
If required, appropriate ALDOT or Baldwin County Highway Department permits shall be obtained prior to the
issuance of a right‐of‐way (ROW) permit.
Contractor is advised to review and comply with the Building Official’s best practices flyer.
Water and Sewer Standard Comments:
All existing utilities must be located, and proper separation shall be maintained between utilities.
All mechanical equipment shall be screened by painting the equipment Munsell Green.
Natural Gas Standard Comments:
Contractor shall provide proper separation from the gas main and all other utilities.
The applicant is advised of the following:
No work shall begin until a ROW permit is issued by the City of Fairhope Building Department or other
applicable jurisdiction (permit not valid until paid for and picked up by contractor).
The ROW permit shall be kept with the contractor or subcontractor at all times during site work. The ROW
permit shall be posted on the job site or in the window of contractor(s) vehicle.
All contractors/subcontractors are subject to City of Fairhope Business License procedures.
This site shall comply with all State, Federal and local requirements, including, but not limited to the following City of
Fairhope Ordinances:
1. City of Fairhope Wetland Ordinance (#1370), which regulates activity within 20' of wetlands.
2. City of Fairhope Red Soil & Clay Ordinance (#1423), which prohibits the use of red soil / clay within 100' of critical
areas.
3. City of Fairhope Erosion and Sediment Control Ordinance (#1398).
State and Federal permits shall be on file with the City of Fairhope Building Department, prior to the issuance of City of
Fairhope permits.
The applicant shall provide as‐built profiles of the installed lines, showing the exact depth.
Recommendation:
Staff recommends approval of UR 19.20 conditional upon the following:
1) The applicant shall follow the general comments related to utility work, as stated above.
2) Applicant and applicant’s contractor shall follow the Right of Way Installation Permitting and Work Procedures
document provided by the Building Official.